Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Biomechanical evaluation of the triangular support structure of the proximal femoral bionic nail compared to conventional long intramedullary nails for subtrochanteric fractures
by
Chen, Wei
, Zhang, Qi
, Zhang, Yingze
, Cheng, Xiaodong
, Wu, Dongwei
, He, Wei
, Yang, Yanjiang
in
Biomechanics
/ Bone density
/ Bone surgery
/ Boundary conditions
/ Design
/ Femur
/ Finite element analysis
/ Finite element method
/ Fractures
/ Mechanical properties
/ Medical research
/ Osteoporosis
/ proximal femoral bionic nail
/ Software
/ subtrochanteric fracture
/ Titanium alloys
/ Transplants & implants
/ triangular support structure
2025
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Biomechanical evaluation of the triangular support structure of the proximal femoral bionic nail compared to conventional long intramedullary nails for subtrochanteric fractures
by
Chen, Wei
, Zhang, Qi
, Zhang, Yingze
, Cheng, Xiaodong
, Wu, Dongwei
, He, Wei
, Yang, Yanjiang
in
Biomechanics
/ Bone density
/ Bone surgery
/ Boundary conditions
/ Design
/ Femur
/ Finite element analysis
/ Finite element method
/ Fractures
/ Mechanical properties
/ Medical research
/ Osteoporosis
/ proximal femoral bionic nail
/ Software
/ subtrochanteric fracture
/ Titanium alloys
/ Transplants & implants
/ triangular support structure
2025
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Biomechanical evaluation of the triangular support structure of the proximal femoral bionic nail compared to conventional long intramedullary nails for subtrochanteric fractures
by
Chen, Wei
, Zhang, Qi
, Zhang, Yingze
, Cheng, Xiaodong
, Wu, Dongwei
, He, Wei
, Yang, Yanjiang
in
Biomechanics
/ Bone density
/ Bone surgery
/ Boundary conditions
/ Design
/ Femur
/ Finite element analysis
/ Finite element method
/ Fractures
/ Mechanical properties
/ Medical research
/ Osteoporosis
/ proximal femoral bionic nail
/ Software
/ subtrochanteric fracture
/ Titanium alloys
/ Transplants & implants
/ triangular support structure
2025
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Biomechanical evaluation of the triangular support structure of the proximal femoral bionic nail compared to conventional long intramedullary nails for subtrochanteric fractures
Journal Article
Biomechanical evaluation of the triangular support structure of the proximal femoral bionic nail compared to conventional long intramedullary nails for subtrochanteric fractures
2025
Request Book From Autostore
and Choose the Collection Method
Overview
The aim of this study was to compare the biomechanical results of long proximal femoral bionic nail (PFBN) and three conventional intramedullary nails in the treatment of subtrochanteric fractures (STFs).
Using finite element analysis, we compared the therapeutic efficacy of four long intramedullary nails: the PFBN, reconstruction nail (RCN), InterTAN nail (ITN), and proximal femoral nail antirotation (PFNA) for the treatment of Seinsheimer type IIIA and type V STFs. The biomechanical stability of the implants was evaluated by calculating of von Mises stress (VMS), contact pressure and displacement for three loading scenarios.
The results showed that the PFBN group had the lowest VMS values under axial, bending and torsional loads. Under axial loading conditions, the VMS of PFBN was 480.04 MPa, followed by ITN (726.39 MPa), PFNA (730.48 MPa), and RCN (837.24 MPa) in the type V fracture groups. In the PFBN group, the contact pressure was 19.22 MPa and the tangential micromotion was 0.089 mm for the type IIIA group, 23.69 MPa and 0.08 mm for the type V group. Compared to the ITN, PFNA and RCN groups, the PFBN group exhibited the lowest contact pressure and tangential micromotion at the fracture sites.
The superior biomechanical properties of the PFBN under axial, bending, and torsional loads not only reduced stress at the fracture site, but also improved structural stability.
Publisher
Frontiers Media SA,Frontiers Media S.A
Subject
This website uses cookies to ensure you get the best experience on our website.