The effect of the entry and re-entry size in the aortic dissection: a two-way fluid–structure interaction simulation
by
Liang, Leo Hwa
, Ho, Jackie P
, Kim, Sangho
, Birgersson, Erik
, Keramati Hamed
, Chua, Kian Jon
in
Aorta
/ Aortic dissection
/ Biomechanics
/ Blood flow
/ Cardiovascular diseases
/ Coronary vessels
/ Dissection
/ Finite element method
/ Flow characteristics
/ Fluid-structure interaction
/ Flutter
/ Injuries
/ Lumens
/ Morbidity
2020
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
The effect of the entry and re-entry size in the aortic dissection: a two-way fluid–structure interaction simulation
by
Liang, Leo Hwa
, Ho, Jackie P
, Kim, Sangho
, Birgersson, Erik
, Keramati Hamed
, Chua, Kian Jon
in
Aorta
/ Aortic dissection
/ Biomechanics
/ Blood flow
/ Cardiovascular diseases
/ Coronary vessels
/ Dissection
/ Finite element method
/ Flow characteristics
/ Fluid-structure interaction
/ Flutter
/ Injuries
/ Lumens
/ Morbidity
2020
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
The effect of the entry and re-entry size in the aortic dissection: a two-way fluid–structure interaction simulation
by
Liang, Leo Hwa
, Ho, Jackie P
, Kim, Sangho
, Birgersson, Erik
, Keramati Hamed
, Chua, Kian Jon
in
Aorta
/ Aortic dissection
/ Biomechanics
/ Blood flow
/ Cardiovascular diseases
/ Coronary vessels
/ Dissection
/ Finite element method
/ Flow characteristics
/ Fluid-structure interaction
/ Flutter
/ Injuries
/ Lumens
/ Morbidity
2020
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
The effect of the entry and re-entry size in the aortic dissection: a two-way fluid–structure interaction simulation
Journal Article
The effect of the entry and re-entry size in the aortic dissection: a two-way fluid–structure interaction simulation
2020
Request Book From Autostore
and Choose the Collection Method
Overview
Aortic dissection (AD) is one of the most catastrophic cardiovascular diseases. AD occurs when a layer inside the aorta is disrupted and gives rise to the formation of a true lumen and a false lumen. These lumens can be connected through tears in the intimal flap which are known as entries. Despite being known for about two centuries, the effects of many factors on the morbidity and mortality of this disease are still unknown. As the blood interaction with the aorta is crucial in the severity and the progression of the aortic dissection, a biomechanical approach is chosen to investigate the influence of different morphologies on the severity of this disease. Using the finite element method (FEM) and the fluid–structure interaction (FSI) approach, we have evaluated the blood flow characteristics along the diseased aorta, in conjunction with the deformation of the aortic wall. In this study, an idealized geometry of a dissected descending aorta (type B) with two entries has been studied. The values for the diameter of the entry tear were chosen to be 5 mm and 10 mm. Therefore, a total of four conditions were investigated. According to our results, the retrograde flow through the proximal tear is dependent on the size of the distal re-entry and vice versa. Our results revealed that when both entry and re-entry tears are 10 mm in diameter, the flow passes through the true and false lumens with smaller resistance, resulting in a smaller flutter of the intimal flap, and therefore more stable intimal flap. Major oscillation frequencies of 2.5 Hz and 7.4 Hz were observed for the oscillation of the intimal flap, and amplitudes of the waves with higher frequencies were negligible.