Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Reliability of Ankle–Foot Complex Isokinetic Strength Assessment Using the Isomed 2000 Dynamometer
by
Linduska, Petr
, Svoboda, Zdenek
, Gonosova, Zuzana
, Bizovska, Lucia
2018
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Reliability of Ankle–Foot Complex Isokinetic Strength Assessment Using the Isomed 2000 Dynamometer
by
Linduska, Petr
, Svoboda, Zdenek
, Gonosova, Zuzana
, Bizovska, Lucia
2018
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Reliability of Ankle–Foot Complex Isokinetic Strength Assessment Using the Isomed 2000 Dynamometer
Journal Article
Reliability of Ankle–Foot Complex Isokinetic Strength Assessment Using the Isomed 2000 Dynamometer
2018
Request Book From Autostore
and Choose the Collection Method
Overview
For quantifying muscle strength in clinical and research practice, establishing the reliability of measurements, specifically to the procedures used, is essential for credible findings. The objective was to establish the reliability of isokinetic measurement of ankle plantar and dorsal flexors (PF/DF) and invertors and evertors (INV/EV) on an IsoMed 2000 dynamometer. Twenty healthy subjects (10 males, 10 females, mean age: 23.1 ± 3.1 years) completed an isokinetic measurement session. The intraclass correlation coefficient (ICC) and standard error of measurement were assessed for peak torque and work of ankle PF/DF (concentric and eccentric) and INV/EV (concentric) for the preferred and nonpreferred limb. Standardized isokinetic measurements of reciprocal PF/DF and INV/EV muscle actions were associated with ICC ranging from 0.77 to 0.98 for the majority of observed parameters. The exception was work in the eccentric mode in the ankle DF and peak torque in the concentric mode in the ankle INV on the preferred limb, where ICC ranged from 0.64 to 0.71. The IsoMed 2000 isokinetic dynamometer can be reliably employed in future studies for reciprocal ankle PF/DF and INV/EV assessment in healthy adult subjects after implementation of a familiarization session.
Publisher
MDPI
MBRLCatalogueRelatedBooks
Related Items
Related Items
We currently cannot retrieve any items related to this title. Kindly check back at a later time.
This website uses cookies to ensure you get the best experience on our website.