Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
A Robust Artificial Bee Colony-Based Load Frequency Control for Hydro-Thermal Interconnected Power System
by
Fathy, Ahmed
, Kassem, Ahmed
, Zaki, Zaki A.
in
Algorithms
/ Bees
/ Control
/ Control systems
/ Design
/ Design and construction
/ Electric power
/ Electric power systems
/ Equipment and supplies
/ Food
/ Hydroelectric power plants
/ Interconnected electric utility systems
/ International interconnected electric utility systems
/ Mathematical optimization
/ Optimization algorithms
/ Optimization techniques
/ Sustainability
2022
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
A Robust Artificial Bee Colony-Based Load Frequency Control for Hydro-Thermal Interconnected Power System
by
Fathy, Ahmed
, Kassem, Ahmed
, Zaki, Zaki A.
in
Algorithms
/ Bees
/ Control
/ Control systems
/ Design
/ Design and construction
/ Electric power
/ Electric power systems
/ Equipment and supplies
/ Food
/ Hydroelectric power plants
/ Interconnected electric utility systems
/ International interconnected electric utility systems
/ Mathematical optimization
/ Optimization algorithms
/ Optimization techniques
/ Sustainability
2022
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
A Robust Artificial Bee Colony-Based Load Frequency Control for Hydro-Thermal Interconnected Power System
by
Fathy, Ahmed
, Kassem, Ahmed
, Zaki, Zaki A.
in
Algorithms
/ Bees
/ Control
/ Control systems
/ Design
/ Design and construction
/ Electric power
/ Electric power systems
/ Equipment and supplies
/ Food
/ Hydroelectric power plants
/ Interconnected electric utility systems
/ International interconnected electric utility systems
/ Mathematical optimization
/ Optimization algorithms
/ Optimization techniques
/ Sustainability
2022
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
A Robust Artificial Bee Colony-Based Load Frequency Control for Hydro-Thermal Interconnected Power System
Journal Article
A Robust Artificial Bee Colony-Based Load Frequency Control for Hydro-Thermal Interconnected Power System
2022
Request Book From Autostore
and Choose the Collection Method
Overview
The presented work examines load frequency control (LFC) to develop the dynamic behavior of the power system under different load disturbances that have occurred in multi-interconnected power systems. An artificial bee colony (ABC) algorithm is proposed to design an optimal proportional integral derivative (PID) controller simulating the LFC installed in a hybrid hydro-thermal interconnected power system. The proposed approach incorporating ABC is employed to determine the optimal parameters of the controller during load disturbance applied on one area. The integral time absolute error (ITAE) of the frequency and exchange power violations is considered as the target to be minimized. Moreover, integral absolute error (IAE) and sum squared error (SSE) are calculated. To prove how the proposed model controller is effective, two-interconnected power systems are presented during a wide range of operating cases, and then the behavior of the proposed controller is compared to that of the designed via a chef-based optimization algorithm (CBOA), seagull optimization approach (SOA), and sine cosine approach. Regarding the 5% disturbance on the thermal plant, the ABC outperformed the other approaches hence achieving the best fitness value of 1.80936, IAE of 3.147938, and SSE of 0.1787486. On the other hand, during a 5% disturbance on the hydro plant, the ABC succeeded in getting ITAE, IAE, and SSE with values of 3.43291, 3.630509, and 0.5233815, respectively. The efficiency and prevalence of the proposed LFC-PID is confirmed by the achieved results.
Publisher
MDPI AG
MBRLCatalogueRelatedBooks
Related Items
Related Items
This website uses cookies to ensure you get the best experience on our website.