Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Predictive Models for Neonatal Follow-Up Serum Bilirubin: Model Development and Validation
by
Chou, Joseph H
in
Original Paper
2020
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Predictive Models for Neonatal Follow-Up Serum Bilirubin: Model Development and Validation
by
Chou, Joseph H
in
Original Paper
2020
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Predictive Models for Neonatal Follow-Up Serum Bilirubin: Model Development and Validation
Journal Article
Predictive Models for Neonatal Follow-Up Serum Bilirubin: Model Development and Validation
2020
Request Book From Autostore
and Choose the Collection Method
Overview
Hyperbilirubinemia affects many newborn infants and, if not treated appropriately, can lead to irreversible brain injury.BACKGROUNDHyperbilirubinemia affects many newborn infants and, if not treated appropriately, can lead to irreversible brain injury.This study aims to develop predictive models of follow-up total serum bilirubin measurement and to compare their accuracy with that of clinician predictions.OBJECTIVEThis study aims to develop predictive models of follow-up total serum bilirubin measurement and to compare their accuracy with that of clinician predictions.Subjects were patients born between June 2015 and June 2019 at 4 hospitals in Massachusetts. The prediction target was a follow-up total serum bilirubin measurement obtained <72 hours after a previous measurement. Birth before versus after February 2019 was used to generate a training set (27,428 target measurements) and a held-out test set (3320 measurements), respectively. Multiple supervised learning models were trained. To further assess model performance, predictions on the held-out test set were also compared with corresponding predictions from clinicians.METHODSSubjects were patients born between June 2015 and June 2019 at 4 hospitals in Massachusetts. The prediction target was a follow-up total serum bilirubin measurement obtained <72 hours after a previous measurement. Birth before versus after February 2019 was used to generate a training set (27,428 target measurements) and a held-out test set (3320 measurements), respectively. Multiple supervised learning models were trained. To further assess model performance, predictions on the held-out test set were also compared with corresponding predictions from clinicians.The best predictive accuracy on the held-out test set was obtained with the multilayer perceptron (ie, neural network, mean absolute error [MAE] 1.05 mg/dL) and Xgboost (MAE 1.04 mg/dL) models. A limited number of predictors were sufficient for constructing models with the best performance and avoiding overfitting: current bilirubin measurement, last rate of rise, proportion of time under phototherapy, time to next measurement, gestational age at birth, current age, and fractional weight change from birth. Clinicians made a total of 210 prospective predictions. The neural network model accuracy on this subset of predictions had an MAE of 1.06 mg/dL compared with clinician predictions with an MAE of 1.38 mg/dL (P<.0001). In babies born at 35 weeks of gestation or later, this approach was also applied to predict the binary outcome of subsequently exceeding consensus guidelines for phototherapy initiation and achieved an area under the receiver operator characteristic curve of 0.94 (95% CI 0.91 to 0.97).RESULTSThe best predictive accuracy on the held-out test set was obtained with the multilayer perceptron (ie, neural network, mean absolute error [MAE] 1.05 mg/dL) and Xgboost (MAE 1.04 mg/dL) models. A limited number of predictors were sufficient for constructing models with the best performance and avoiding overfitting: current bilirubin measurement, last rate of rise, proportion of time under phototherapy, time to next measurement, gestational age at birth, current age, and fractional weight change from birth. Clinicians made a total of 210 prospective predictions. The neural network model accuracy on this subset of predictions had an MAE of 1.06 mg/dL compared with clinician predictions with an MAE of 1.38 mg/dL (P<.0001). In babies born at 35 weeks of gestation or later, this approach was also applied to predict the binary outcome of subsequently exceeding consensus guidelines for phototherapy initiation and achieved an area under the receiver operator characteristic curve of 0.94 (95% CI 0.91 to 0.97).This study developed predictive models for neonatal follow-up total serum bilirubin measurements that outperform clinicians. This may be the first report of models that predict specific bilirubin values, are not limited to near-term patients without risk factors, and take into account the effect of phototherapy.CONCLUSIONSThis study developed predictive models for neonatal follow-up total serum bilirubin measurements that outperform clinicians. This may be the first report of models that predict specific bilirubin values, are not limited to near-term patients without risk factors, and take into account the effect of phototherapy.
Publisher
JMIR Publications
Subject
This website uses cookies to ensure you get the best experience on our website.