Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Implementation of DSK TMS320C6416T Module in Modified Stethoscope for Lung Sound Detection
by
Homzah, Ozkar F.
, Muslimin, S
, Pratama, D A
, Prihatini, E
, Husni, N L
in
Acoustics
/ Auscultation
/ Design modifications
/ DSP module
/ Fourier transforms
/ Frequency ranges
/ Lung sounds detection
/ Lungs
/ Physicians
/ Physics
/ Signs and symptoms
/ Sound
/ STFT and Wavelet method
/ Wavelet transforms
2020
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Implementation of DSK TMS320C6416T Module in Modified Stethoscope for Lung Sound Detection
by
Homzah, Ozkar F.
, Muslimin, S
, Pratama, D A
, Prihatini, E
, Husni, N L
in
Acoustics
/ Auscultation
/ Design modifications
/ DSP module
/ Fourier transforms
/ Frequency ranges
/ Lung sounds detection
/ Lungs
/ Physicians
/ Physics
/ Signs and symptoms
/ Sound
/ STFT and Wavelet method
/ Wavelet transforms
2020
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Implementation of DSK TMS320C6416T Module in Modified Stethoscope for Lung Sound Detection
by
Homzah, Ozkar F.
, Muslimin, S
, Pratama, D A
, Prihatini, E
, Husni, N L
in
Acoustics
/ Auscultation
/ Design modifications
/ DSP module
/ Fourier transforms
/ Frequency ranges
/ Lung sounds detection
/ Lungs
/ Physicians
/ Physics
/ Signs and symptoms
/ Sound
/ STFT and Wavelet method
/ Wavelet transforms
2020
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Implementation of DSK TMS320C6416T Module in Modified Stethoscope for Lung Sound Detection
Journal Article
Implementation of DSK TMS320C6416T Module in Modified Stethoscope for Lung Sound Detection
2020
Request Book From Autostore
and Choose the Collection Method
Overview
This paper presents a design of digital stethoscope that is modified using DSK TMS320C6416T. This modified stethoscope is proposed for helping the doctor to make a true decision and the same perception on the symptoms of someone's disease. Using the conventional stethoscope usually gives drawback, such as the doctors usually makes misinterpretation on the auscultation. The reason is because of the errors that occur due to the difference on the sensitivity of the ear and the experiences of the doctor. This research offers a DSK TMS 320C6416T as an instrumentation system for identification and analysis on the lung sound. The modified design of the digital stethoscope that is proposed in this research gives benefit to the users because it provides the result in the form of the signals that can be monitored in the PC. The results of this designed stethoscope showed the interpretation of graphs in the form of the spectrogram and scalogram which will help the simplification on the analysis of lung sounds as well as to minimize or avoid the limitations of hearing problems in the process of auscultation. The method used in lung sound analysis in this research includes Fourier Transformation that is then developed into a Short-Time Fourier transform (STFT) and continued to the Wavelet Transform. Based on the test data for normal lung sounds, it was found that the working frequency range was 90 to 1265 Hz. The adventitious sounds were found with frequency range from 60 to 1980 Hz. In this research, it was also found that the lung sounds were at the frequency range from 90 to 1015 Hz for direct measurement to patients.
Publisher
IOP Publishing
This website uses cookies to ensure you get the best experience on our website.