MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Total body irradiation: A transition from a Co‐60 treatment unit to an IMRT lateral‐field extended‐SAD technique
Total body irradiation: A transition from a Co‐60 treatment unit to an IMRT lateral‐field extended‐SAD technique
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Total body irradiation: A transition from a Co‐60 treatment unit to an IMRT lateral‐field extended‐SAD technique
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Total body irradiation: A transition from a Co‐60 treatment unit to an IMRT lateral‐field extended‐SAD technique
Total body irradiation: A transition from a Co‐60 treatment unit to an IMRT lateral‐field extended‐SAD technique

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Total body irradiation: A transition from a Co‐60 treatment unit to an IMRT lateral‐field extended‐SAD technique
Total body irradiation: A transition from a Co‐60 treatment unit to an IMRT lateral‐field extended‐SAD technique
Journal Article

Total body irradiation: A transition from a Co‐60 treatment unit to an IMRT lateral‐field extended‐SAD technique

2024
Request Book From Autostore and Choose the Collection Method
Overview
Purpose The purpose of this work was to detail our center's experience in transitioning from a Co‐60 treatment technique to an intensity modulated radiation therapy (IMRT) based lateral‐field extended source‐to‐axis distance (e‐SAD) technique for total body irradiation (TBI). Materials and Methods An existing beam model in RayStation v.10A was validated for the use of e‐SAD TBI treatments. Data were acquired with an Elekta Synergy linear accelerator (LINAC) at an extended source‐to‐surface distance of 365 cm with an 18 MV beam. Beam model validation measurements included percentage depth dose (PDD), profile data, surface dose, build‐up region and transmission measurements. End‐to‐end testing was carried out using an anthropomorphic phantom. Treatments were performed in a supine position in a whole‐body Vac‐Lok at an e‐SAD of 400 cm with a beam spoiler 10 cm from the couch. Planning was achieved using IMRT, where multi‐leaf collimators were used to modulate the beam and shield the organs at risk. Beam's eye view projection images were used for in‐room patient positioning and in‐vivo dosimetry was performed for every treatment. Results The percent difference between the measured and calculated PDD and profiles was less than 2% at all locations. Surface dose was 83.8% of the maximum dose with the beam spoiler at a 10 cm distance from the phantom. The largest percent difference between the treatment planning system (TPS) and measured data within the anthropomorphic phantom was approximately 2%. In‐vivo dosimetry measurements yielded results within the 5% institutional threshold. Conclusion In 2022, 17 patients were successfully treated using the new IMRT‐based lateral‐field e‐SAD TBI technique. The resulting clinical plans respected the institutional standard. The commissioning process, as well as the treatment planning and delivery aspects were described in this work with the intention of supporting other clinics in implementing this treatment method.