Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Total body irradiation: A transition from a Co‐60 treatment unit to an IMRT lateral‐field extended‐SAD technique
by
Roussin, Étienne
, Bernard, Maryse
, Brunet‐Benkhoucha, Malik
, Marchand, Eve‐Lyne
, St‐Pierre, Julie
, Kolokotronis, Anastasia
in
extended‐SSD IMRT
/ Kidney diseases
/ Lungs
/ Radiation Oncology Physics
/ Radiation therapy
/ TBI commissioning
/ TBI treatment planning
/ total body irradiation (TBI)
/ Toxicity
/ Transplants & implants
/ Water
2024
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Total body irradiation: A transition from a Co‐60 treatment unit to an IMRT lateral‐field extended‐SAD technique
by
Roussin, Étienne
, Bernard, Maryse
, Brunet‐Benkhoucha, Malik
, Marchand, Eve‐Lyne
, St‐Pierre, Julie
, Kolokotronis, Anastasia
in
extended‐SSD IMRT
/ Kidney diseases
/ Lungs
/ Radiation Oncology Physics
/ Radiation therapy
/ TBI commissioning
/ TBI treatment planning
/ total body irradiation (TBI)
/ Toxicity
/ Transplants & implants
/ Water
2024
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Total body irradiation: A transition from a Co‐60 treatment unit to an IMRT lateral‐field extended‐SAD technique
by
Roussin, Étienne
, Bernard, Maryse
, Brunet‐Benkhoucha, Malik
, Marchand, Eve‐Lyne
, St‐Pierre, Julie
, Kolokotronis, Anastasia
in
extended‐SSD IMRT
/ Kidney diseases
/ Lungs
/ Radiation Oncology Physics
/ Radiation therapy
/ TBI commissioning
/ TBI treatment planning
/ total body irradiation (TBI)
/ Toxicity
/ Transplants & implants
/ Water
2024
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Total body irradiation: A transition from a Co‐60 treatment unit to an IMRT lateral‐field extended‐SAD technique
Journal Article
Total body irradiation: A transition from a Co‐60 treatment unit to an IMRT lateral‐field extended‐SAD technique
2024
Request Book From Autostore
and Choose the Collection Method
Overview
Purpose The purpose of this work was to detail our center's experience in transitioning from a Co‐60 treatment technique to an intensity modulated radiation therapy (IMRT) based lateral‐field extended source‐to‐axis distance (e‐SAD) technique for total body irradiation (TBI). Materials and Methods An existing beam model in RayStation v.10A was validated for the use of e‐SAD TBI treatments. Data were acquired with an Elekta Synergy linear accelerator (LINAC) at an extended source‐to‐surface distance of 365 cm with an 18 MV beam. Beam model validation measurements included percentage depth dose (PDD), profile data, surface dose, build‐up region and transmission measurements. End‐to‐end testing was carried out using an anthropomorphic phantom. Treatments were performed in a supine position in a whole‐body Vac‐Lok at an e‐SAD of 400 cm with a beam spoiler 10 cm from the couch. Planning was achieved using IMRT, where multi‐leaf collimators were used to modulate the beam and shield the organs at risk. Beam's eye view projection images were used for in‐room patient positioning and in‐vivo dosimetry was performed for every treatment. Results The percent difference between the measured and calculated PDD and profiles was less than 2% at all locations. Surface dose was 83.8% of the maximum dose with the beam spoiler at a 10 cm distance from the phantom. The largest percent difference between the treatment planning system (TPS) and measured data within the anthropomorphic phantom was approximately 2%. In‐vivo dosimetry measurements yielded results within the 5% institutional threshold. Conclusion In 2022, 17 patients were successfully treated using the new IMRT‐based lateral‐field e‐SAD TBI technique. The resulting clinical plans respected the institutional standard. The commissioning process, as well as the treatment planning and delivery aspects were described in this work with the intention of supporting other clinics in implementing this treatment method.
Publisher
John Wiley & Sons, Inc,John Wiley and Sons Inc
This website uses cookies to ensure you get the best experience on our website.