Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
A Double-Blind, Randomized, Sham-Controlled Trial of the Effect of a Radiation-Attenuating Drape on Radiation Exposure to Endoscopy Staff During ERCP
by
Ciarleglio, Maria M
, Aslanian, Harry R
, Jamidar, Priya A
, Muniraj, Thiruvengadam
, Farrell, James
, Deng, Yanhong
, Ho, Henry
, Laine, Loren
in
Absorption, Radiation
/ Cholangiopancreatography, Endoscopic Retrograde
/ Double-Blind Method
/ Eye
/ Fluoroscopy
/ Gastroenterology
/ Humans
/ Neck
/ Nursing Staff
/ Occupational Exposure - prevention & control
/ Prospective Studies
/ Protective Devices
/ Radiation Dosage
/ Radiation Protection - instrumentation
/ Radiation Protection - methods
2015
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
A Double-Blind, Randomized, Sham-Controlled Trial of the Effect of a Radiation-Attenuating Drape on Radiation Exposure to Endoscopy Staff During ERCP
by
Ciarleglio, Maria M
, Aslanian, Harry R
, Jamidar, Priya A
, Muniraj, Thiruvengadam
, Farrell, James
, Deng, Yanhong
, Ho, Henry
, Laine, Loren
in
Absorption, Radiation
/ Cholangiopancreatography, Endoscopic Retrograde
/ Double-Blind Method
/ Eye
/ Fluoroscopy
/ Gastroenterology
/ Humans
/ Neck
/ Nursing Staff
/ Occupational Exposure - prevention & control
/ Prospective Studies
/ Protective Devices
/ Radiation Dosage
/ Radiation Protection - instrumentation
/ Radiation Protection - methods
2015
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
A Double-Blind, Randomized, Sham-Controlled Trial of the Effect of a Radiation-Attenuating Drape on Radiation Exposure to Endoscopy Staff During ERCP
by
Ciarleglio, Maria M
, Aslanian, Harry R
, Jamidar, Priya A
, Muniraj, Thiruvengadam
, Farrell, James
, Deng, Yanhong
, Ho, Henry
, Laine, Loren
in
Absorption, Radiation
/ Cholangiopancreatography, Endoscopic Retrograde
/ Double-Blind Method
/ Eye
/ Fluoroscopy
/ Gastroenterology
/ Humans
/ Neck
/ Nursing Staff
/ Occupational Exposure - prevention & control
/ Prospective Studies
/ Protective Devices
/ Radiation Dosage
/ Radiation Protection - instrumentation
/ Radiation Protection - methods
2015
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
A Double-Blind, Randomized, Sham-Controlled Trial of the Effect of a Radiation-Attenuating Drape on Radiation Exposure to Endoscopy Staff During ERCP
Journal Article
A Double-Blind, Randomized, Sham-Controlled Trial of the Effect of a Radiation-Attenuating Drape on Radiation Exposure to Endoscopy Staff During ERCP
2015
Request Book From Autostore
and Choose the Collection Method
Overview
Endoscopic retrograde cholangiopancreatography (ERCP) is associated with radiation exposure to the endoscopist and staff that may be significant in high-volume centers. We investigated whether a radiation-attenuating drape over the fluoroscopy image intensifier reduces radiation exposure during ERCP.
We performed a prospective, randomized, double-blind trial of 100 therapeutic ERCPs at a tertiary-care university center. Procedures were randomly assigned to groups receiving lead-free radiation-attenuating drapes (n=50) or identical sham drapes (n=50). The drapes were suspended around the fluoroscopy image intensifier during ERCP. The primary end point was the effective dose of radiation measured at the endoscopist's eye and neck, and at the assisting nurse's neck. The cumulative annual radiation exposure was also estimated.
Fluoroscopy time, absorbed radiation dose, and dose area product were similar in the study groups. Mean effective dose for sham vs. radiation-attenuating drape was 0.21±0.27 vs. 0.02±0.02 mSv at the endoscopist's eye, 0.35±0.44 vs. 0.03±0.03 mSv at the endoscopist's neck, and 0.27±0.34 vs. 0.02±0.02 mSv at the nurse's neck (P<0.0001 for all comparisons). The relative risk reduction in radiation was 90%, 91%, and 93% at the three sites. At a high-volume center in which an endoscopist performs 500 therapeutic ERCPs per year, the estimated cumulative annual effective dose at the endoscopist's eye level is 126 mSv with conventional protection and 12 mSv with a radiation-attenuating drape, with the recommended limit being 20 mSv.
The addition of a radiation-attenuating drape around the image intensifier during ERCP significantly decreases radiation exposure to endoscopists and staff by ∼90%.
Publisher
Wolters Kluwer Health Medical Research, Lippincott Williams & Wilkins
This website uses cookies to ensure you get the best experience on our website.