MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Day to day treatment variations of accelerated partial breast brachytherapy using a multi-lumen balloon
Day to day treatment variations of accelerated partial breast brachytherapy using a multi-lumen balloon
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Day to day treatment variations of accelerated partial breast brachytherapy using a multi-lumen balloon
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Day to day treatment variations of accelerated partial breast brachytherapy using a multi-lumen balloon
Day to day treatment variations of accelerated partial breast brachytherapy using a multi-lumen balloon

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Day to day treatment variations of accelerated partial breast brachytherapy using a multi-lumen balloon
Day to day treatment variations of accelerated partial breast brachytherapy using a multi-lumen balloon
Journal Article

Day to day treatment variations of accelerated partial breast brachytherapy using a multi-lumen balloon

2014
Request Book From Autostore and Choose the Collection Method
Overview
To evaluate the variations of multi-lumen balloon (MLB)-based brachytherapy from simulation day to treatment day and their dosimetric impacts during accelerated partial breast irradiation (APBI). A total of 42 CT images scanned from seven patients were evaluated with regards to daily variation due to of: 1) internal uncertainty: size and shape of balloon, seroma volume; 2) geometrical uncertainty-random: length of each catheter was measured for each fraction (total 70); 3) geometrical uncertainty-systematic: virtual systematic errors were tested by offsetting dwell positions. The original plans (as group A) had a mean value of 96.8% on V95 of the PTV_Eval. Plans were rerun (as group B) such that the mean value of the V95 was relaxed to 90.4%. By applying the reference plan to each daily CT image, variations of target coverage under different sources of error were evaluated. Shape and size of the balloon had means of < 1 mm decreased in diameter and < 0.4 cm(3) decreased in volume; the mean seroma volume increased by 0.2 cm(3). This internal variation has a mean of < 1% difference for both V90 and V95. The geometrical uncertainty made a mean deviation of 2.7 mm per root of sum of square. It caused the degradations of V90 and V95 by mean values of 1.0% and 1.2%, respectively. A systematic error of 3 mm and 4 mm would degrade both of V90 and V95 by 4% and 6%, respectively. The degradations on target coverage of the plans in group A were statistically the same as those in group B. Overall, APBI treatments with MLB based brachytherapy are precise from day to day. However, minor variation due to daily treatment uncertainties can still degrade tumor bed coverage to an unacceptable coverage when V95 of the original plan is close to 90%.