Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
The influence of different sets of surgical instrumentation in Oxford UKA on bearing size and component position
by
Walker, Tilman
, Streit, Marcus R
, Heinemann, Pascal
, Kinkel, Stefan
, Bruckner, Thomas
, Gotterbarm, Tobias
in
Joint surgery
/ Knee
2017
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
The influence of different sets of surgical instrumentation in Oxford UKA on bearing size and component position
by
Walker, Tilman
, Streit, Marcus R
, Heinemann, Pascal
, Kinkel, Stefan
, Bruckner, Thomas
, Gotterbarm, Tobias
in
Joint surgery
/ Knee
2017
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
The influence of different sets of surgical instrumentation in Oxford UKA on bearing size and component position
Journal Article
The influence of different sets of surgical instrumentation in Oxford UKA on bearing size and component position
2017
Request Book From Autostore
and Choose the Collection Method
Overview
IntroductionThe Oxford unicompartmental knee arthroplasty (OUKA) has been proven to be an effective treatment for anteromedial osteoarthritis of the knee joint. New instrumentation has been introduced to improve the reproducibility of implant positioning and to minimize bone loss during tibial resection (Oxford Microplasty; Zimmer Biomet, Warsaw, Indiana, USA).MethodsTo assess the effect of the new instrumentation, we retrospectively evaluated the postoperative radiographs and surgical records of 300 OUKAs in three consecutive cohorts of patients. The first cohort consists of the first 100 minimal invasive implantations of the OUKA using the conventional phase III instrumentation, the second cohort consists of the 100 most recent minimal invasive OUKA with the conventional phase III instrumentation and the third cohort consists of the first 100 minimal invasive OUKA using the new Oxford Microplasty instrumentation.ResultsMean bearing thickness was statistically significant and lower in OUKA with use of the updated instrumentation than with the conventional instrumentation (p = 0.01 and p = 0.04). Additionally, statistically significant and more femoral components were aligned within the accepted range of tolerance in both the coronal and the sagittal plane with use of the updated instrumentation compared to the conventional phase III instrumentation in group A (p = 0.029 and p = 0.038) and in the sagittal plane with use of the updated instrumentation compared to the conventional phase III instrumentation in group B (p = 0.002).ConclusionThe new modified instrumentation seems to be an effective tool to reduce the risk of malalignment of the femoral component in the coronal and in the sagittal plane compared to the conventional phase III instrumentation. Furthermore, the instrumentation is also effective in determining an adequate level of tibial resection and thus avoiding unnecessary bone loss.
Publisher
Springer Nature B.V
Subject
This website uses cookies to ensure you get the best experience on our website.