Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
An internal magnet traction device reduces procedure time for endoscopic submucosal dissection by expert and non-expert endoscopists: ex vivo study in a porcine colorectal model (with video)
by
Gostout, Christopher J
, Deters, Jodie L
, Tholen, Crystal J
, Louis M Wong Kee Song
, Rajan, Elizabeth
, Miller, Charles A
, Dobashi, Akira
, Storm, Andrew C
in
Colorectal cancer
/ Dissection
/ Endoscopy
/ Feasibility studies
/ Gastric cancer
/ Tumors
2019
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
An internal magnet traction device reduces procedure time for endoscopic submucosal dissection by expert and non-expert endoscopists: ex vivo study in a porcine colorectal model (with video)
by
Gostout, Christopher J
, Deters, Jodie L
, Tholen, Crystal J
, Louis M Wong Kee Song
, Rajan, Elizabeth
, Miller, Charles A
, Dobashi, Akira
, Storm, Andrew C
in
Colorectal cancer
/ Dissection
/ Endoscopy
/ Feasibility studies
/ Gastric cancer
/ Tumors
2019
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
An internal magnet traction device reduces procedure time for endoscopic submucosal dissection by expert and non-expert endoscopists: ex vivo study in a porcine colorectal model (with video)
by
Gostout, Christopher J
, Deters, Jodie L
, Tholen, Crystal J
, Louis M Wong Kee Song
, Rajan, Elizabeth
, Miller, Charles A
, Dobashi, Akira
, Storm, Andrew C
in
Colorectal cancer
/ Dissection
/ Endoscopy
/ Feasibility studies
/ Gastric cancer
/ Tumors
2019
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
An internal magnet traction device reduces procedure time for endoscopic submucosal dissection by expert and non-expert endoscopists: ex vivo study in a porcine colorectal model (with video)
Journal Article
An internal magnet traction device reduces procedure time for endoscopic submucosal dissection by expert and non-expert endoscopists: ex vivo study in a porcine colorectal model (with video)
2019
Request Book From Autostore
and Choose the Collection Method
Overview
BackgroundEfficacy of an internal magnet traction device (MTD) for gastric endoscopic submucosal dissection (ESD) by an expert endoscopist has been reported. We hypothesized that use of the MTD would enhance the performance of colorectal ESD in a non-expert endoscopist in ESD compared to the conventional technique. Primary aim of this study was to compare procedure times between conventional ESD (C-ESD) and MTD-assisted ESD (MTD-ESD) by expert and non-expert endoscopists in ESD. Secondary aims included rate of en bloc resection, iatrogenic injury, visualization score of the submucosal layer, and endoscopist satisfaction score.MethodsA total of 56 lesions were created in an ex vivo porcine colorectum. Two endoscopists completed C-ESD (n = 28) and MTD-ESD (n = 28). Lesions measured 3 cm in diameter and were located on either the anterior or posterior colorectal wall. The MTD consisted of a small neodymium magnet and nylon monofilament attached to a through-the-scope clip. The first MTD was deployed on the opposing colorectal wall of the target lesion and a second MTD was then deployed directly onto the distal margin of the lesion.ResultsTotal procedure time for MTD-ESD was significantly shorter than C-ESD for both expert (median: 15.8 vs. 19.3 min, p < 0.05) and non-expert (median: 21.3 vs. 33.9 min, p < 0.001) endoscopists. All lesions were resected en bloc. There was no iatrogenic muscularis propria injury in the MTD-ESD group. For both the expert and non-expert, scores for MTD-ESD were significantly higher for submucosal layer visualization (p < 0.05) and endoscopist satisfaction (p < 0.001) compared to C-ESD.ConclusionsUse of the MTD significantly reduced procedure time for both expert and non-expert endoscopists performing ESD. Improving the efficiency, safety, and satisfaction of ESD with such a device particularly for non-expert endoscopists is appealing and could potentially minimize the complexity and duration of the procedure allowing for more widespread use of the technique.
Publisher
Springer Nature B.V
Subject
This website uses cookies to ensure you get the best experience on our website.