MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Inter- and intra-observer reliability of patellar height measurements in patients with and without patellar instability on plain radiographs and magnetic resonance imaging
Inter- and intra-observer reliability of patellar height measurements in patients with and without patellar instability on plain radiographs and magnetic resonance imaging
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Inter- and intra-observer reliability of patellar height measurements in patients with and without patellar instability on plain radiographs and magnetic resonance imaging
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Inter- and intra-observer reliability of patellar height measurements in patients with and without patellar instability on plain radiographs and magnetic resonance imaging
Inter- and intra-observer reliability of patellar height measurements in patients with and without patellar instability on plain radiographs and magnetic resonance imaging

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Inter- and intra-observer reliability of patellar height measurements in patients with and without patellar instability on plain radiographs and magnetic resonance imaging
Inter- and intra-observer reliability of patellar height measurements in patients with and without patellar instability on plain radiographs and magnetic resonance imaging
Journal Article

Inter- and intra-observer reliability of patellar height measurements in patients with and without patellar instability on plain radiographs and magnetic resonance imaging

2022
Request Book From Autostore and Choose the Collection Method
Overview
Abstract IntroductionMany patella height indices exist in the literature. There is no single universally accepted radiological assessment for measuring patella height. The aims of this study were to determine which of the commonly used indices can most reliably measure patella height and compare the findings on both plain X-ray and magnetic resonance imaging (MRI) of the knee.MethodsThis case-controlled study compared patients with recurrent patella instability (patella group) to a control group. Two observers measured six validated patella height indices on X-ray and MRI of both groups at two separate time periods. Between-group and within-group statistical analysis was undertaken of the data. The inter- and intra-observer reliability was assessed using the intraclass correlation coefficient (ICC) and the kappa measure of agreement (k).ResultsForty-four patients comprised the patella group and 50 patients the control group. There was a significant difference of most indices between the two groups (p < 0.05). There was a significant difference of most indices between the two imaging modalities (p < 0.05). The Insall-Salvati ratio had the greatest inter-observer reliability for both X-ray and MRI (ICC = 0.79 to 0.97; p < 0.001) (k = 0.50 to 1.00; p < 0.001).ConclusionPatella height indices significantly differ when measured on X-ray as compared to MRI. This may infer that a different set of normative values are required for each radiological modality, which we have proposed in this study. Overall, the Insall-Salvati ratio performed best and shows a high degree of intra- and inter-observer reliability on both X-ray and MRI.