Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Influence of Implant Number on Peri-Implant and Posterior Edentulous Area Strains in Mandibular Overdentures Retained by the New Ti–Zr (Roxolid®) Mini-Implants as Single-Units: In Vitro Study
by
Petricevic, Nikola
, Celebic, Asja
, Kovacic, Ines
, Puljic, Dario
in
Dental implants
/ Dentures
/ Design
/ different number of mini-implants
/ Edentulous
/ Implant dentures
/ loading forces
/ mandibular overdenture
/ Mechanical properties
/ Polymerization
/ Retention
/ single units
/ Software
/ Strain gauges
/ Ti–Zr mini-implants
2024
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Influence of Implant Number on Peri-Implant and Posterior Edentulous Area Strains in Mandibular Overdentures Retained by the New Ti–Zr (Roxolid®) Mini-Implants as Single-Units: In Vitro Study
by
Petricevic, Nikola
, Celebic, Asja
, Kovacic, Ines
, Puljic, Dario
in
Dental implants
/ Dentures
/ Design
/ different number of mini-implants
/ Edentulous
/ Implant dentures
/ loading forces
/ mandibular overdenture
/ Mechanical properties
/ Polymerization
/ Retention
/ single units
/ Software
/ Strain gauges
/ Ti–Zr mini-implants
2024
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Influence of Implant Number on Peri-Implant and Posterior Edentulous Area Strains in Mandibular Overdentures Retained by the New Ti–Zr (Roxolid®) Mini-Implants as Single-Units: In Vitro Study
by
Petricevic, Nikola
, Celebic, Asja
, Kovacic, Ines
, Puljic, Dario
in
Dental implants
/ Dentures
/ Design
/ different number of mini-implants
/ Edentulous
/ Implant dentures
/ loading forces
/ mandibular overdenture
/ Mechanical properties
/ Polymerization
/ Retention
/ single units
/ Software
/ Strain gauges
/ Ti–Zr mini-implants
2024
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Influence of Implant Number on Peri-Implant and Posterior Edentulous Area Strains in Mandibular Overdentures Retained by the New Ti–Zr (Roxolid®) Mini-Implants as Single-Units: In Vitro Study
Journal Article
Influence of Implant Number on Peri-Implant and Posterior Edentulous Area Strains in Mandibular Overdentures Retained by the New Ti–Zr (Roxolid®) Mini-Implants as Single-Units: In Vitro Study
2024
Request Book From Autostore
and Choose the Collection Method
Overview
The new Ti–Zr (Roxolid®) mini-implants have not yet been fully researched. We analyzed peri-implant and posterior edentulous area microstrains during mandibular overdenture (OD) loading at different sites with different extents of forces when one-, two-, three-, or four- mini dental implants (MDIs) as single-units supported the respective ODs. The models were designed from cone beam computed tomography (CBCT) scans of an appropriate patient with narrow ridges. The mucosal thickness was 2 mm. Strain gauges were bonded on the vestibular and oral peri-implant sites, and in the distal edentulous area under the saddles. The loads were applied posteriorly bilaterally and unilaterally with 50, 100 and 150 N forces, and anteriorly with 50 and 100 N forces. Each loading was repeated 15 times. Statistical analysis included descriptive statistics, boxplots and the MANOVA. Higher forces induced higher peri-implant microstrains, as well as unilateral loadings, especially on the loaded side, in all models except the one-MDI model where anterior loads (100 N) elicited the highest peri-implant microstrain (1719.35 ± 76.0). The highest microstrains during unilateral posterior loading (right side) with 150 N force were registered from the right MDI in the two-MDI model (1836.64 ± 63.0). High microstrains were also recorded on the left side (1444.48 ± 54.6). By increasing the number of implants, peri-implant microstrains and those in the edentulous area decreased. In the three- and four-MDI models, higher microstrains were found in the posterior than in the anterior MDIs under posterior loadings. None of the recorded microstrains exceeded bone reparatory mechanisms, although precaution and additional research should be provided when only one or two MDIs support ODs.
Publisher
MDPI AG
This website uses cookies to ensure you get the best experience on our website.