Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Fluorescence optosensors based on different transducers for the determination of polycyclic aromatic hydrocarbons in water
by
Cruces-Blanco, C.
, Fern ndez-S nchez, J. F.
, Sanz-Medel, A.
, Fern ndez-Guti rrez, A.
, Pereiro, R.
, Bordel, N.
, Costa-Fern ndez, J. M.
, Segura-Carretero, A.
2003
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Fluorescence optosensors based on different transducers for the determination of polycyclic aromatic hydrocarbons in water
by
Cruces-Blanco, C.
, Fern ndez-S nchez, J. F.
, Sanz-Medel, A.
, Fern ndez-Guti rrez, A.
, Pereiro, R.
, Bordel, N.
, Costa-Fern ndez, J. M.
, Segura-Carretero, A.
2003
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Fluorescence optosensors based on different transducers for the determination of polycyclic aromatic hydrocarbons in water
Journal Article
Fluorescence optosensors based on different transducers for the determination of polycyclic aromatic hydrocarbons in water
2003
Request Book From Autostore
and Choose the Collection Method
Overview
This paper presents the development of two optosensors for the determination of four polycyclic aromatic hydrocarbons (anthracene, benzo[a]pyrene, fluoranthene and benzo[b]fluoranthene) using a photomultiplier device and an intensified coupled charge device (ICCD) as optical transducers, respectively. These optosensors are based on the on-line immobilization of the analytes onto a non-ionic resin solid support (Amberlite XAD-4) in a continuous flow system, followed by the measurement of their native fluorescence. The determinations were performed using 15 mM H(2)PO(4)(-)/HPO(4)(2-) buffer solution at pH 7 and 25% 1,4-dioxane. Detection limits were 6.4 and 9.3 for ANT, 3.3 and 2.5 for BbF, 1.4 and 13.2 for FLT, and 1.7 and 7.8 for BaP using optosensor 1 or 2, respectively. Relative standard deviations were 7.9 and 6.7 for ANT at 50 ng mL(-1), 3.5 and 7.4 for BbF at 60 ng mL(-1), 3.6 and 8.9 for FLT at 50 ng mL(-1), and 6.7 and 11.6 for BaP at 50 ng mL(-1) using optosensor 1 or 2, respectively. Finally, a critical comparison between the two configurations based on different transducers (photomultiplier and ICCD) for resolving and simultaneously determining mixtures of the polycyclic aromatic hydrocarbons under study in water samples (tap and mineral waters) were carried out.
MBRLCatalogueRelatedBooks
Related Items
Related Items
We currently cannot retrieve any items related to this title. Kindly check back at a later time.
This website uses cookies to ensure you get the best experience on our website.