Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Functional assessment of a new extended depth-of-focus intraocular lens
by
Alessio, Giovanni
, Carbonara, Claudio
, Frugis, Nicola
, Savini, Giacomo
, Bellucci, Roberto
, Balducci, Nicole
, Altieri, Manuel
, Zappulla, Emilia
, Rossi, Scipione
in
Acuity
/ Binocular vision
/ Cataracts
/ Surgery
2019
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Functional assessment of a new extended depth-of-focus intraocular lens
by
Alessio, Giovanni
, Carbonara, Claudio
, Frugis, Nicola
, Savini, Giacomo
, Bellucci, Roberto
, Balducci, Nicole
, Altieri, Manuel
, Zappulla, Emilia
, Rossi, Scipione
in
Acuity
/ Binocular vision
/ Cataracts
/ Surgery
2019
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Functional assessment of a new extended depth-of-focus intraocular lens
Journal Article
Functional assessment of a new extended depth-of-focus intraocular lens
2019
Request Book From Autostore
and Choose the Collection Method
Overview
Background/objectiveThis study aimed to investigate the visual performance of a new extended depth-of-focus intraocular lens (EDOF-IOL).Subjects/methodsIn this multicenter, prospective, observational study, we enrolled 97 patients who underwent cataract surgery or refractive lens exchange with implantation of the Mini Well EDOF-IOL (SIFI, Italy). Patients underwent postoperatively the following examinations between 4 and 8 weeks after surgery: corrected distance visual acuity (CDVA), reading speed with Radner’s chart, distance-corrected near visual acuity (DCNVA), defocus curve, contrast sensitivity, and haloes quantitative assessment.ResultsIn the whole sample, the mean monocular CDVA and DCNVA were, respectively, 0.02 ± 0.07 logMAR and 0.38 ± 0.15 logRAD (logarithm of the reading acuity determination). In the 67 bilaterally implanted patients, binocular CDVA and DCNVA were better (0.00 ± 0.05 logMAR and 0.26 ± 0.13 logRAD) than the corresponding monocular values (p = 0.02 and p = 0.0002, respectively). Ninety-two percent of patients bilaterally implanted reached a binocular reading speed >80 words per minute at a 0.5 logRAD print size (corresponding to the common book print size). The defocus curves showed that the EDOF-IOL provided increased depth of focus through 2.0 D of defocus, with the best performance at 1.0 and 1.5 D. Contrast sensitivity was within normal limits at all spatial frequencies. The mean visual disturbance index was 0.08 ± 0.12, suggesting low night visual disturbances.ConclusionsThe new EDOF-IOL provided good visual acuity for distance, intermediate, and near vision, with no loss of contrast sensitivity and low risk of night visual disturbances.
Publisher
Nature Publishing Group
Subject
MBRLCatalogueRelatedBooks
Related Items
Related Items
We currently cannot retrieve any items related to this title. Kindly check back at a later time.
This website uses cookies to ensure you get the best experience on our website.