Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Lower-limb internal loading and potential consequences for fracture healing
by
Duda, Georg N.
, Deppe, Dominik
, Heyland, Mark
, Reisener, Marie Jacqueline
, Trepczynski, Adam
, Reinke, Simon
, Taylor, William R.
, Damm, Philipp
in
Bioengineering and Biotechnology
/ Body weight
/ Bone healing
/ Bones
/ Boundary conditions
/ Compression
/ Femur
/ fracture fixation
/ Fractures
/ internal bone loading
/ intramedullary nail
/ Kinematics
/ Knee
/ locking plate
/ Long bone
/ Mechanical loading
/ Patients
/ Surgery
/ Tibia
/ Tissue engineering
2023
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Lower-limb internal loading and potential consequences for fracture healing
by
Duda, Georg N.
, Deppe, Dominik
, Heyland, Mark
, Reisener, Marie Jacqueline
, Trepczynski, Adam
, Reinke, Simon
, Taylor, William R.
, Damm, Philipp
in
Bioengineering and Biotechnology
/ Body weight
/ Bone healing
/ Bones
/ Boundary conditions
/ Compression
/ Femur
/ fracture fixation
/ Fractures
/ internal bone loading
/ intramedullary nail
/ Kinematics
/ Knee
/ locking plate
/ Long bone
/ Mechanical loading
/ Patients
/ Surgery
/ Tibia
/ Tissue engineering
2023
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Lower-limb internal loading and potential consequences for fracture healing
by
Duda, Georg N.
, Deppe, Dominik
, Heyland, Mark
, Reisener, Marie Jacqueline
, Trepczynski, Adam
, Reinke, Simon
, Taylor, William R.
, Damm, Philipp
in
Bioengineering and Biotechnology
/ Body weight
/ Bone healing
/ Bones
/ Boundary conditions
/ Compression
/ Femur
/ fracture fixation
/ Fractures
/ internal bone loading
/ intramedullary nail
/ Kinematics
/ Knee
/ locking plate
/ Long bone
/ Mechanical loading
/ Patients
/ Surgery
/ Tibia
/ Tissue engineering
2023
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Lower-limb internal loading and potential consequences for fracture healing
Journal Article
Lower-limb internal loading and potential consequences for fracture healing
2023
Request Book From Autostore
and Choose the Collection Method
Overview
Introduction: Mechanical loading is known to determine the course of bone fracture healing. We hypothesise that lower limb long bone loading differs with knee flexion angle during walking and frontal knee alignment, which affects fracture healing success. Materials and methods: Using our musculoskeletal in silico modelling constrained against in vivo data from patients with instrumented knee implants allowed us to assess internal loads in femur and tibia. These internal forces were associated with the clinical outcome of fracture healing in a relevant cohort of 178 extra-articular femur and tibia fractures in patients using a retrospective approach. Results: Mean peak forces differed with femoral compression (1,330–1,936 N at mid-shaft) amounting to about half of tibial compression (2,299–5,224 N). Mean peak bending moments in the frontal plane were greater in the femur (71–130 Nm) than in the tibia (from 26 to 43 Nm), each increasing proximally. Bending in the sagittal plane showed smaller mean peak bending moments in the femur (−38 to 43 Nm) reaching substantially higher values in the tibia (−63 to −175 Nm) with a peak proximally. Peak torsional moments had opposite directions for the femur (−13 to −40 Nm) versus tibia (15–48 Nm) with an increase towards the proximal end in both. Femoral fractures showed significantly lower scores in the modified Radiological Union Scale for Tibia (mRUST) at last follow-up ( p < 0.001) compared to tibial fractures. Specifically, compression ( r = 0.304), sagittal bending ( r = 0.259), and frontal bending ( r = −0.318) showed strong associations ( p < 0.001) to mRUST at last follow-up. This was not the case for age, body weight, or localisation alone. Discussion: This study showed that moments in femur and tibia tend to decrease towards their distal ends. Tibial load components were influenced by knee flexion angle, especially at push-off, while static frontal alignment played a smaller role. Our results indicate that femur and tibia are loaded differently and thus require adapted fracture fixation considering load components rather than just overall load level.
This website uses cookies to ensure you get the best experience on our website.