Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Biomechanical modeling of transcatheter aortic valve replacement in a stenotic bicuspid aortic valve: deployments and paravalvular leakage
by
Marom, Gil
, Haj-Ali, Rami
, Raanani, Ehud
, Hamdan, Ashraf
, Lavon, Karin
, Morany, Adi
, Bluestein, Danny
, Bianchi, Matteo
, Halevi, Rotem
in
Aortic valve
/ Biomechanics
/ Calcification
/ Calcium
/ Computational fluid dynamics
/ Computed tomography
/ Computer applications
/ Computer simulation
/ Coronary artery disease
/ Electrocardiography
/ Heart diseases
/ Implants
/ Leakage
/ Mathematical models
/ Rheumatic heart disease
/ Stents
/ Surgeons
/ Surgical implants
/ Valve leaflets
2019
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Biomechanical modeling of transcatheter aortic valve replacement in a stenotic bicuspid aortic valve: deployments and paravalvular leakage
by
Marom, Gil
, Haj-Ali, Rami
, Raanani, Ehud
, Hamdan, Ashraf
, Lavon, Karin
, Morany, Adi
, Bluestein, Danny
, Bianchi, Matteo
, Halevi, Rotem
in
Aortic valve
/ Biomechanics
/ Calcification
/ Calcium
/ Computational fluid dynamics
/ Computed tomography
/ Computer applications
/ Computer simulation
/ Coronary artery disease
/ Electrocardiography
/ Heart diseases
/ Implants
/ Leakage
/ Mathematical models
/ Rheumatic heart disease
/ Stents
/ Surgeons
/ Surgical implants
/ Valve leaflets
2019
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Biomechanical modeling of transcatheter aortic valve replacement in a stenotic bicuspid aortic valve: deployments and paravalvular leakage
by
Marom, Gil
, Haj-Ali, Rami
, Raanani, Ehud
, Hamdan, Ashraf
, Lavon, Karin
, Morany, Adi
, Bluestein, Danny
, Bianchi, Matteo
, Halevi, Rotem
in
Aortic valve
/ Biomechanics
/ Calcification
/ Calcium
/ Computational fluid dynamics
/ Computed tomography
/ Computer applications
/ Computer simulation
/ Coronary artery disease
/ Electrocardiography
/ Heart diseases
/ Implants
/ Leakage
/ Mathematical models
/ Rheumatic heart disease
/ Stents
/ Surgeons
/ Surgical implants
/ Valve leaflets
2019
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Biomechanical modeling of transcatheter aortic valve replacement in a stenotic bicuspid aortic valve: deployments and paravalvular leakage
Journal Article
Biomechanical modeling of transcatheter aortic valve replacement in a stenotic bicuspid aortic valve: deployments and paravalvular leakage
2019
Request Book From Autostore
and Choose the Collection Method
Overview
Calcific aortic valve disease (CAVD) is characterized by stiffened aortic valve leaflets. Bicuspid aortic valve (BAV) is the most common congenital heart disease. Transcatheter aortic valve replacement (TAVR) is a treatment approach for CAVD where a stent with mounted bioprosthetic valve is deployed on the stenotic valve. Performing TAVR in calcified BAV patients may be associated with post-procedural complications due to the BAV asymmetrical structure. This study aims to develop refined computational models simulating the deployments of Evolut R and PRO TAVR devices in a representative calcified BAV. The paravalvular leakage (PVL) was also calculated by computational fluid dynamics simulations. Computed tomography scan of severely stenotic BAV patient was acquired. The 3D calcium deposits were generated and embedded inside a parametric model of the BAV. Deployments of the Evolut R and PRO inside the calcified BAV were simulated in five bioprosthesis leaflet orientations. The hypothesis of asymmetric and elliptic stent deployment was confirmed. Positioning the bioprosthesis commissures aligned with the native commissures yielded the lowest PVL (15.7 vs. 29.5 mL/beat). The Evolut PRO reduced the PVL in half compared with the Evolut R (15.7 vs. 28.7 mL/beat). The proposed biomechanical computational model could optimize future TAVR treatment in BAV patients.
This website uses cookies to ensure you get the best experience on our website.