Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Encouraged 6-min Walking Test Indicates Maximum Sustainable Exercise in COPD Patients
by
Barberà, Joan Albert
, Rodriguez-Roisin, Robert
, Mayer, Anamaria
, Vilaro, Jordi
, Casas, Alejandro
, Rabinovich, Roberto
, Roca, Josep
in
6-min walking test
/ Aged
/ Analysis of Variance
/ Biological and medical sciences
/ Cardiology. Vascular system
/ Chronic obstructive pulmonary disease
/ COPD
/ critical power
/ Exercise Test - methods
/ exercise testing
/ exercise tolerance
/ Exercise Tolerance - physiology
/ Heart rate
/ Humans
/ Male
/ Medical sciences
/ Middle Aged
/ Oxygen Consumption
/ Patients
/ Pneumology
/ Pulmonary Disease, Chronic Obstructive - physiopathology
/ Respiratory Function Tests
/ Sustainability
/ sustainable submaximal exercise
/ Variance analysis
/ Walking - physiology
2005
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Encouraged 6-min Walking Test Indicates Maximum Sustainable Exercise in COPD Patients
by
Barberà, Joan Albert
, Rodriguez-Roisin, Robert
, Mayer, Anamaria
, Vilaro, Jordi
, Casas, Alejandro
, Rabinovich, Roberto
, Roca, Josep
in
6-min walking test
/ Aged
/ Analysis of Variance
/ Biological and medical sciences
/ Cardiology. Vascular system
/ Chronic obstructive pulmonary disease
/ COPD
/ critical power
/ Exercise Test - methods
/ exercise testing
/ exercise tolerance
/ Exercise Tolerance - physiology
/ Heart rate
/ Humans
/ Male
/ Medical sciences
/ Middle Aged
/ Oxygen Consumption
/ Patients
/ Pneumology
/ Pulmonary Disease, Chronic Obstructive - physiopathology
/ Respiratory Function Tests
/ Sustainability
/ sustainable submaximal exercise
/ Variance analysis
/ Walking - physiology
2005
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Encouraged 6-min Walking Test Indicates Maximum Sustainable Exercise in COPD Patients
by
Barberà, Joan Albert
, Rodriguez-Roisin, Robert
, Mayer, Anamaria
, Vilaro, Jordi
, Casas, Alejandro
, Rabinovich, Roberto
, Roca, Josep
in
6-min walking test
/ Aged
/ Analysis of Variance
/ Biological and medical sciences
/ Cardiology. Vascular system
/ Chronic obstructive pulmonary disease
/ COPD
/ critical power
/ Exercise Test - methods
/ exercise testing
/ exercise tolerance
/ Exercise Tolerance - physiology
/ Heart rate
/ Humans
/ Male
/ Medical sciences
/ Middle Aged
/ Oxygen Consumption
/ Patients
/ Pneumology
/ Pulmonary Disease, Chronic Obstructive - physiopathology
/ Respiratory Function Tests
/ Sustainability
/ sustainable submaximal exercise
/ Variance analysis
/ Walking - physiology
2005
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Encouraged 6-min Walking Test Indicates Maximum Sustainable Exercise in COPD Patients
Journal Article
Encouraged 6-min Walking Test Indicates Maximum Sustainable Exercise in COPD Patients
2005
Request Book From Autostore
and Choose the Collection Method
Overview
In patients with moderate-to-severe COPD, an encouraged 6-min walking test (6MWT) is a high-intensity submaximal exercise protocol that shows an oxygen uptake ( V˙o2) plateau after the third minute of the test. This last feature prompted the hypothesis that self-paced walking speed is set to achieve “maximal” sustainable V˙o2, namely “critical power” or “critical speed.”
Eight patients with moderate-to-severe COPD (mean age, 68 ± 7 years [± SD]; FEV1, 50 ± 13% predicted; Pao2, 69 ± 8 mm Hg) underwent the following tests on different days in order: (1) encouraged 6MWT; (2) standard incremental shuttle test to identify peak walking speed; (3) four different high-intensity, constant walking speed tests to exhaustion to calculate critical walking speed; and (4) timed walking test at critical walking speed (CWS) to examine sustainability of the exercise.
6MWT and CWS showed similar results (mean of last 3 min): V˙o2 (1,605 ± 304 mL/min vs 1,584 ± 319 mL/min), minute ventilation (47 ± 12 L/min vs 48 ± 11 L/min), respiratory exchange ratio (0.89 ± 0.1 vs 0.90 ± 0.1), heart rate (130 ± 18 beats/min vs 131 ± 16 beats/min), Borg dyspnea score (5.4 ± 1.3 vs 5.5 ± 2.4), and walking speed (1.49 ± 0.1 m/s vs 1.44 ± 0.1 m/s, respectively).
This study supports that 6MWT indicates maximum sustainable exercise that might be related with its predictive value in COPD patients.
Publisher
Elsevier Inc,American College of Chest Physicians
This website uses cookies to ensure you get the best experience on our website.