Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
The Effect of Full Protective Gear on Intubation Performance by Hospital Medical Personnel
by
Segal, Eran
, Perel, Azriel
, Wiener, Michael
, Nahtomi, Orit
, Meyerovitch, Joseph
, Hendler, Israel
in
Adult
/ Anesthesia
/ Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy
/ Anesthesia: equipment, devices
/ Anesthesiology
/ Biological and medical sciences
/ Chemical Warfare
/ Clinical Competence - standards
/ Cross-Over Studies
/ Decontamination
/ Humans
/ Intubation
/ Intubation, Intratracheal - standards
/ Medical personnel
/ Medical sciences
/ Medical Staff, Hospital
/ Nurses
/ Nursing Staff, Hospital
/ Personal protective equipment
/ Poisoning
/ Prospective Studies
/ Protective Clothing - adverse effects
/ Suctioning
/ Teams
/ Time Factors
2000
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
The Effect of Full Protective Gear on Intubation Performance by Hospital Medical Personnel
by
Segal, Eran
, Perel, Azriel
, Wiener, Michael
, Nahtomi, Orit
, Meyerovitch, Joseph
, Hendler, Israel
in
Adult
/ Anesthesia
/ Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy
/ Anesthesia: equipment, devices
/ Anesthesiology
/ Biological and medical sciences
/ Chemical Warfare
/ Clinical Competence - standards
/ Cross-Over Studies
/ Decontamination
/ Humans
/ Intubation
/ Intubation, Intratracheal - standards
/ Medical personnel
/ Medical sciences
/ Medical Staff, Hospital
/ Nurses
/ Nursing Staff, Hospital
/ Personal protective equipment
/ Poisoning
/ Prospective Studies
/ Protective Clothing - adverse effects
/ Suctioning
/ Teams
/ Time Factors
2000
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
The Effect of Full Protective Gear on Intubation Performance by Hospital Medical Personnel
by
Segal, Eran
, Perel, Azriel
, Wiener, Michael
, Nahtomi, Orit
, Meyerovitch, Joseph
, Hendler, Israel
in
Adult
/ Anesthesia
/ Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy
/ Anesthesia: equipment, devices
/ Anesthesiology
/ Biological and medical sciences
/ Chemical Warfare
/ Clinical Competence - standards
/ Cross-Over Studies
/ Decontamination
/ Humans
/ Intubation
/ Intubation, Intratracheal - standards
/ Medical personnel
/ Medical sciences
/ Medical Staff, Hospital
/ Nurses
/ Nursing Staff, Hospital
/ Personal protective equipment
/ Poisoning
/ Prospective Studies
/ Protective Clothing - adverse effects
/ Suctioning
/ Teams
/ Time Factors
2000
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
The Effect of Full Protective Gear on Intubation Performance by Hospital Medical Personnel
Journal Article
The Effect of Full Protective Gear on Intubation Performance by Hospital Medical Personnel
2000
Request Book From Autostore
and Choose the Collection Method
Overview
To assess the influence of protective gear on intubation performance.
Prospective, controlled measurement of duration and quality of intubations performed on mannequins by medical personnel with and without protective gear in a crossover design.
Eight teams each comprising an anesthesiologist and a nurse.
Intubation duration with and without chemical warfare gear was 69.2 +/- 7 and 47.3 +/- 6 seconds (mean +/- SEM), respectively (p < 0.05). Moreover, rating of intubation quality as \"very good\" by the anesthesiologists declined significantly from 62.5% without chemical warfare protective gear to 6.25% with the garment and mask. Tube fixation was the rate-limiting step when performed with protective gear (p < 0.05); it was assessed by 81% of the anesthesiologists as the critical step. A learning curve was not observed during the study.
Protective gear causes a significant prolongation of intubation duration; however, endotracheal intubation can be performed effectively. Technical improvements are warranted for tube fixation because it is the critical step.
Publisher
Association of Military Surgeons,Oxford University Press
Subject
/ Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy
/ Anesthesia: equipment, devices
/ Biological and medical sciences
/ Clinical Competence - standards
/ Humans
/ Intubation, Intratracheal - standards
/ Nurses
/ Personal protective equipment
/ Protective Clothing - adverse effects
/ Teams
This website uses cookies to ensure you get the best experience on our website.