Comparison of Bead-Based Fluorescence Versus Planar Electrochemiluminescence Multiplex Immunoassays for Measuring Cytokines in Human Plasma
by
Joos, Thomas
, Günther, Anna
, Göpfert, Jens
, Schneiderhan-Marra, Nicole
, Becker, Matthias
in
Biomarkers
/ Calibration
/ chemokine
/ cytokine
/ Cytokines
/ Diabetes
/ dynamic range
/ Expenditures
/ FDA approval
/ Fluorescence
/ Immunoassay
/ Immunology
/ Interleukin 17
/ Interleukin 6
/ lower limit of quantification
/ Meso Scale Discovery
/ multiplex immunoassay
/ Plasma
/ Proteins
/ Quality control
/ Quality standards
/ Sepsis
2020
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Comparison of Bead-Based Fluorescence Versus Planar Electrochemiluminescence Multiplex Immunoassays for Measuring Cytokines in Human Plasma
by
Joos, Thomas
, Günther, Anna
, Göpfert, Jens
, Schneiderhan-Marra, Nicole
, Becker, Matthias
in
Biomarkers
/ Calibration
/ chemokine
/ cytokine
/ Cytokines
/ Diabetes
/ dynamic range
/ Expenditures
/ FDA approval
/ Fluorescence
/ Immunoassay
/ Immunology
/ Interleukin 17
/ Interleukin 6
/ lower limit of quantification
/ Meso Scale Discovery
/ multiplex immunoassay
/ Plasma
/ Proteins
/ Quality control
/ Quality standards
/ Sepsis
2020
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Comparison of Bead-Based Fluorescence Versus Planar Electrochemiluminescence Multiplex Immunoassays for Measuring Cytokines in Human Plasma
by
Joos, Thomas
, Günther, Anna
, Göpfert, Jens
, Schneiderhan-Marra, Nicole
, Becker, Matthias
in
Biomarkers
/ Calibration
/ chemokine
/ cytokine
/ Cytokines
/ Diabetes
/ dynamic range
/ Expenditures
/ FDA approval
/ Fluorescence
/ Immunoassay
/ Immunology
/ Interleukin 17
/ Interleukin 6
/ lower limit of quantification
/ Meso Scale Discovery
/ multiplex immunoassay
/ Plasma
/ Proteins
/ Quality control
/ Quality standards
/ Sepsis
2020
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Comparison of Bead-Based Fluorescence Versus Planar Electrochemiluminescence Multiplex Immunoassays for Measuring Cytokines in Human Plasma
Journal Article
Comparison of Bead-Based Fluorescence Versus Planar Electrochemiluminescence Multiplex Immunoassays for Measuring Cytokines in Human Plasma
2020
Request Book From Autostore
and Choose the Collection Method
Overview
This study compared two 96-well multiplex immunoassay platforms for analytical performance in assessing cytokine concentrations in standards, quality controls and human plasma samples (
= 62), and evaluated assay time requirements. Assays included a bead-based fluorescence MILLIPLEX
assay/Luminex fluorescence platform (LMX) and three kits from Meso Scale Discovery (MSD) in planar electrochemiluminescence format. The LMX kit evaluated 21 cytokines and the MSD kits evaluated 10 cytokines each, with 16 overlapping cytokines between platforms. Both assays provided good reproducibility in standard curves for all analytes. Interassay CVs of shared analytes showed average kit quality control CVs ranging 1.9-18.2% for LMX and 2.4-13.9% for MSD. The MSD platform had lower LLoQs than LMX for 14/16 shared cytokines. For IL-17, the LLoQ was lower with LMX than MSD, and the LLoQs for IL-6 were similar. Although MSD calibration curves indicated lower LLoQs for most of those analytes, many more cytokines in human plasma samples were not detected by MSD than by LMX. The ULoQs were higher in LMX versus MSD assays for 13/16 shared analytes, lower than MSD for IL-17, and equivalent between assays for IL-6 and MIP-1α. Bland-Altman plots indicated that MSD classified 13/16 shared analytes as concentrations lower than by LMX. Time and motion analysis indicated that total mean assay times were 20 h 28 m and 21 h 33 m for LMX and MSD, respectively, including an overnight (17 h) incubation. The MSD assays employed a manufacturer-approved overnight incubation instead of the standard 2-h incubation, which kit instructions suggest might increase detection sensitivity. Hands-on labor time averaged 1 h 37 m for LMX and 2 h 33 m for MSD. In summary, assay selection factors should include selection of specific markers of interest, time and cost considerations, and anticipated cytokine concentrations in prospective samples.