Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Level of Activity Changes Increases the Fatigue Life of the Porous Magnesium Scaffold, as Observed in Dynamic Immersion Tests, over Time
by
Basri, Hasan
, Akbar, Imam
, Syahrom, Ardiyansyah
, Putra, Risky Utama
, Ammarullah, Muhammad Imam
, Prakoso, Akbar Teguh
, Chandra, Hendri
, Kamarul, Tunku
in
Biomechanics
/ Bone regeneration
/ Bones
/ Fatigue
/ Fatigue testing machines
/ Implants, Artificial
/ Magnesium
/ Materials
/ Materials research
/ Prosthesis
/ Software
/ Transplants & implants
2023
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Level of Activity Changes Increases the Fatigue Life of the Porous Magnesium Scaffold, as Observed in Dynamic Immersion Tests, over Time
by
Basri, Hasan
, Akbar, Imam
, Syahrom, Ardiyansyah
, Putra, Risky Utama
, Ammarullah, Muhammad Imam
, Prakoso, Akbar Teguh
, Chandra, Hendri
, Kamarul, Tunku
in
Biomechanics
/ Bone regeneration
/ Bones
/ Fatigue
/ Fatigue testing machines
/ Implants, Artificial
/ Magnesium
/ Materials
/ Materials research
/ Prosthesis
/ Software
/ Transplants & implants
2023
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Level of Activity Changes Increases the Fatigue Life of the Porous Magnesium Scaffold, as Observed in Dynamic Immersion Tests, over Time
by
Basri, Hasan
, Akbar, Imam
, Syahrom, Ardiyansyah
, Putra, Risky Utama
, Ammarullah, Muhammad Imam
, Prakoso, Akbar Teguh
, Chandra, Hendri
, Kamarul, Tunku
in
Biomechanics
/ Bone regeneration
/ Bones
/ Fatigue
/ Fatigue testing machines
/ Implants, Artificial
/ Magnesium
/ Materials
/ Materials research
/ Prosthesis
/ Software
/ Transplants & implants
2023
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Level of Activity Changes Increases the Fatigue Life of the Porous Magnesium Scaffold, as Observed in Dynamic Immersion Tests, over Time
Journal Article
Level of Activity Changes Increases the Fatigue Life of the Porous Magnesium Scaffold, as Observed in Dynamic Immersion Tests, over Time
2023
Request Book From Autostore
and Choose the Collection Method
Overview
In the present study, the effects of human physiological activity levels on the fatigue life of a porous magnesium scaffold have been investigated. First, the dynamic immersion and biomechanical testing are carried out on a porous magnesium scaffold to simulate the physiological conditions. Then, a numerical data analysis and computer simulations predict the implant failure values. A 3D CAD bone scaffold model was used to predict the implant fatigue, based on the micro-tomographic images. This study uses a simulation of solid mechanics and fatigue, based on daily physiological activities, which include walking, running, and climbing stairs, with strains reaching 1000–3500 µm/mm. The porous magnesium scaffold with a porosity of 41% was put through immersion tests for 24, 48, and 72 h in a typical simulated body fluid. Longer immersion times resulted in increased fatigue, with cycles of failure (Nf) observed to decrease from 4.508 × 1022 to 2.286 × 1011 (1.9 × 1011 fold decrease) after 72 hours of immersion with a loading rate of 1000 µm/mm. Activities played an essential role in the rate of implant fatigue, such as demonstrated by the 1.1 × 105 fold increase in the Nf of walking versus stair climbing at 7.603 × 1011 versus 6.858 × 105, respectively. The dynamic immersion tests could establish data on activity levels when an implant fails over time. This information could provide a basis for more robust future implant designs.
Publisher
MDPI AG
Subject
This website uses cookies to ensure you get the best experience on our website.