MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Pole Allocation Applied to Two Buildings Connected by Joint Damper
Pole Allocation Applied to Two Buildings Connected by Joint Damper
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Pole Allocation Applied to Two Buildings Connected by Joint Damper
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Pole Allocation Applied to Two Buildings Connected by Joint Damper
Pole Allocation Applied to Two Buildings Connected by Joint Damper

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Pole Allocation Applied to Two Buildings Connected by Joint Damper
Pole Allocation Applied to Two Buildings Connected by Joint Damper
Journal Article

Pole Allocation Applied to Two Buildings Connected by Joint Damper

2024
Request Book From Autostore and Choose the Collection Method
Overview
For two adjacent buildings connected by a joint damper, an inverse problem is formulated based on the pole allocation method in control theory. The structural system is simplified as a two-degrees-of-freedom (2-DOF) lumped-mass damped shear model. The unified governing equation, which expresses the relationship between an assigned control target and the structural parameters for an earthquake-resistant building, seismically isolated building, or passively controlled building, is extended to structural control using a joint damper. The introduced equation automatically constrains the variations in the structural parameters under the assigned modal properties. The integration of the pole allocation method and fixed-point theory directly estimates the additional damping effect on the target buildings from the optimum capacity of the joint damper, which improves the trial-and-error steps at the preliminary design stage. The past fixed-point theories do not provide the additional damping effect but the optimum damping coefficient of the joint damper. The present study directly links the additional damping with the damping of the joint damper. Numerical examples are used to verify the theoretical integration using a 20-DOF building model wherein two 10-DOF models are connected by a joint damper between the top lumped masses.