MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Study of Residual Stress Using Phased Array Ultrasonics in Ti-6AL-4V Wire-Arc Additively Manufactured Components
Study of Residual Stress Using Phased Array Ultrasonics in Ti-6AL-4V Wire-Arc Additively Manufactured Components
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Study of Residual Stress Using Phased Array Ultrasonics in Ti-6AL-4V Wire-Arc Additively Manufactured Components
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Study of Residual Stress Using Phased Array Ultrasonics in Ti-6AL-4V Wire-Arc Additively Manufactured Components
Study of Residual Stress Using Phased Array Ultrasonics in Ti-6AL-4V Wire-Arc Additively Manufactured Components

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Study of Residual Stress Using Phased Array Ultrasonics in Ti-6AL-4V Wire-Arc Additively Manufactured Components
Study of Residual Stress Using Phased Array Ultrasonics in Ti-6AL-4V Wire-Arc Additively Manufactured Components
Journal Article

Study of Residual Stress Using Phased Array Ultrasonics in Ti-6AL-4V Wire-Arc Additively Manufactured Components

2024
Request Book From Autostore and Choose the Collection Method
Overview
This paper presents a study on residual stress measurement in wire-arc additively manufactured (WAAM) titanium samples using the non-destructive method of phased array ultrasonics. The contour method (CM) was used for the verification of the phased array ultrasonic results. This allowed for a comparison of measurement methods to understand the effects on the distribution of residual stress (RS) within Ti-6Al-4V samples and the effectiveness of measurement of residual stress using phased array ultrasonics. From the results of the experiments, the phased array ultrasonic data were found to be in good agreement with the CM results and displayed similar residual stress distributions in the samples. The results of the individual elements of the phased array were also compared and an improvement in accuracy was found. From per-element results, anomalies were found and could be mitigated with the ability to average the results by using phased array ultrasonics. Therefore, based on these results, there is a strong case for the benefits of using phased array ultrasonics as a method of residual stress measurement for WAAM Ti-6Al-4V components over other existing residual stress measurement techniques.