MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Spatial specificity of the functional MRI blood oxygenation response relative to neuronal activity
Spatial specificity of the functional MRI blood oxygenation response relative to neuronal activity
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Spatial specificity of the functional MRI blood oxygenation response relative to neuronal activity
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Spatial specificity of the functional MRI blood oxygenation response relative to neuronal activity
Spatial specificity of the functional MRI blood oxygenation response relative to neuronal activity

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Spatial specificity of the functional MRI blood oxygenation response relative to neuronal activity
Spatial specificity of the functional MRI blood oxygenation response relative to neuronal activity
Journal Article

Spatial specificity of the functional MRI blood oxygenation response relative to neuronal activity

2018
Request Book From Autostore and Choose the Collection Method
Overview
Previous attempts at characterizing the spatial specificity of the blood oxygenation level dependent functional MRI (BOLD fMRI) response by estimating its point-spread function (PSF) have conventionally relied on retinotopic spatial representations of visual stimuli in area V1. Consequently, their estimates were confounded by the width and scatter of receptive fields of V1 neurons. Here, we circumvent these limits by instead using the inherent cortical spatial organization of ocular dominance columns (ODCs) to determine the PSF for both Gradient Echo (GE) and Spin Echo (SE) BOLD imaging at 7 Tesla. By applying Markov chain Monte Carlo sampling on a probabilistic generative model of imaging ODCs, we quantified the PSFs that best predict the spatial structure and magnitude of differential ODCs' responses. Prior distributions for the ODC model parameters were determined by analyzing published data of cytochrome oxidase patterns from post-mortem histology of human V1 and of neurophysiological ocular dominance indices. The average PSF full-widths at half-maximum obtained from differential ODCs’ responses following the removal of voxels influenced by contributions from macroscopic blood vessels were 0.86 mm (SE) and 0.99 mm (GE). Our results provide a quantitative basis for the spatial specificity of BOLD fMRI at ultra-high fields, which can be used for planning and interpretation of high-resolution differential fMRI of fine-scale cortical organizations. [Display omitted] •The spread of BOLD response was previously estimated with retinotopic stimuli.•Previous estimates were confounded by width and scatter of neuronal receptive fields.•We apply Markov Chain Monte Carlo sampling to fit a model of imaging columns to data.•Average FWHM of BOLD spread, following blood vessel removal: 0.86 mm (SE) and 0.99 mm (GE).•Our findings support planning and interpretation of high-resolution differential fMRI.