Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Failure of concordance of the Farnsworth D15 test and the Nagel anomaloscope matching range in anomalous trichromatism
by
BIRCH, JENNIFER
in
Anomalous trichromats
/ Biological and medical sciences
/ Color Perception - physiology
/ Color Perception Tests - instrumentation
/ Color Perception Tests - methods
/ Color Vision Defects - classification
/ Color Vision Defects - diagnosis
/ D15
/ Discrimination (Psychology)
/ Eye and associated structures. Visual pathways and centers. Vision
/ Fundamental and applied biological sciences. Psychology
/ Humans
/ Nagel anomaloscope
/ Predictive Value of Tests
/ Reproducibility of Results
/ Vertebrates: nervous system and sense organs
/ Vision Screening - instrumentation
/ Vision Screening - methods
2008
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Failure of concordance of the Farnsworth D15 test and the Nagel anomaloscope matching range in anomalous trichromatism
by
BIRCH, JENNIFER
in
Anomalous trichromats
/ Biological and medical sciences
/ Color Perception - physiology
/ Color Perception Tests - instrumentation
/ Color Perception Tests - methods
/ Color Vision Defects - classification
/ Color Vision Defects - diagnosis
/ D15
/ Discrimination (Psychology)
/ Eye and associated structures. Visual pathways and centers. Vision
/ Fundamental and applied biological sciences. Psychology
/ Humans
/ Nagel anomaloscope
/ Predictive Value of Tests
/ Reproducibility of Results
/ Vertebrates: nervous system and sense organs
/ Vision Screening - instrumentation
/ Vision Screening - methods
2008
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Failure of concordance of the Farnsworth D15 test and the Nagel anomaloscope matching range in anomalous trichromatism
by
BIRCH, JENNIFER
in
Anomalous trichromats
/ Biological and medical sciences
/ Color Perception - physiology
/ Color Perception Tests - instrumentation
/ Color Perception Tests - methods
/ Color Vision Defects - classification
/ Color Vision Defects - diagnosis
/ D15
/ Discrimination (Psychology)
/ Eye and associated structures. Visual pathways and centers. Vision
/ Fundamental and applied biological sciences. Psychology
/ Humans
/ Nagel anomaloscope
/ Predictive Value of Tests
/ Reproducibility of Results
/ Vertebrates: nervous system and sense organs
/ Vision Screening - instrumentation
/ Vision Screening - methods
2008
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Failure of concordance of the Farnsworth D15 test and the Nagel anomaloscope matching range in anomalous trichromatism
Journal Article
Failure of concordance of the Farnsworth D15 test and the Nagel anomaloscope matching range in anomalous trichromatism
2008
Request Book From Autostore
and Choose the Collection Method
Overview
The Farnsworth D15 test (D15) was developed for use in occupational guidance. People with significant color deficiency, including all dichromats are expected to fail and people with slight color deficiency are expected to pass. Pass is a circular results diagram and fail an interlacing pattern with one or more red-green isochromatic errors (Farnsworth, 1947). The Nagel anomaloscope is a “gold standard” reference test for identifying and classifying red-green color deficiency. The matching range on the red/green mixture scale indicates the severity of the discrimination deficit. Pass/fail results for the D15 are presented for 107 protanomalous and 410 deuteranomalous trichromats and compared with the anomaloscope matching range. Thirty-six percent of the subjects examined failed the D15. Protanomalous trichromats are able to utilize perceived luminance contrast to obtain good results on the D15 but 42% of these subjects failed the D15 compared with 35% of deuteranomalous subjects. Failure of the D15 was clearly related to the Nagel matching range in deuteranomalous trichromatism but not in protanomalous trichromatism. For example, 84% of deuteranomalous subjects with matching ranges > 30 scale units failed the D15 but only 2% with matching ranges < 9 scale units were unsuccessful. In comparison, 53% of protanomalous subjects with matching ranges > 15 scale units and 33% of subjects with matching ranges < 5 scale units were unsuccessful. Protanomalous trichromats with apparently minimal color deficiency are therefore shown to have poor practical hue discrimination ability as measured with this test.
Publisher
Cambridge University Press
Subject
/ Biological and medical sciences
/ Color Perception - physiology
/ Color Perception Tests - instrumentation
/ Color Perception Tests - methods
/ Color Vision Defects - classification
/ Color Vision Defects - diagnosis
/ D15
/ Eye and associated structures. Visual pathways and centers. Vision
/ Fundamental and applied biological sciences. Psychology
/ Humans
/ Vertebrates: nervous system and sense organs
This website uses cookies to ensure you get the best experience on our website.