MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Predictive validity of a novel non-invasive estimation of effective shunt fraction in critically ill patients
Predictive validity of a novel non-invasive estimation of effective shunt fraction in critically ill patients
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Predictive validity of a novel non-invasive estimation of effective shunt fraction in critically ill patients
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Predictive validity of a novel non-invasive estimation of effective shunt fraction in critically ill patients
Predictive validity of a novel non-invasive estimation of effective shunt fraction in critically ill patients

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Predictive validity of a novel non-invasive estimation of effective shunt fraction in critically ill patients
Predictive validity of a novel non-invasive estimation of effective shunt fraction in critically ill patients
Journal Article

Predictive validity of a novel non-invasive estimation of effective shunt fraction in critically ill patients

2019
Request Book From Autostore and Choose the Collection Method
Overview
Background Accurate measurement of pulmonary oxygenation is important for classification of disease severity and quantification of outcomes in clinical studies. Currently, tension-based methods such as P/F ratio are in widespread use, but are known to be less accurate than content-based methods. However, content-based methods require invasive measurements or sophisticated equipment that are rarely used in clinical practice. We devised two new methods to infer shunt fraction from a single arterial blood gas sample: (1) a non-invasive effective shunt (ES) fraction calculated using a rearrangement of the indirect Fick equation, standard constants, and a procedural inversion of the relationship between content and tension and (2) inferred values from a database of outputs from an integrated mathematical model of gas exchange (DB). We compared the predictive validity—the accuracy of predictions of P a O 2 following changes in F I O 2 —of each measure in a retrospective database of 78,159 arterial blood gas (ABG) results from critically ill patients. Results In a formal test set comprising 9,635 pairs of ABGs, the median absolute error (MAE) values for the four measures were as follows: alveolar-arterial difference, 7.30 kPa; P a O 2 /F I O 2 ratio, 2.41 kPa; DB, 2.13 kPa; and ES, 1.88 kPa. ES performed significantly better than other measures ( p < 10-10 in all comparisons). Further exploration of the DB method demonstrated that obtaining two blood gas measurements at different F I O 2 provides a more precise description of pulmonary oxygenation. Conclusions Effective shunt can be calculated using a computationally efficient procedure using routinely collected arterial blood gas data and has better predictive validity than other analytic methods. For practical assessment of oxygenation in clinical research, ES should be used in preference to other indices. ES can be calculated at http://baillielab.net/es .
Publisher
Springer International Publishing,Springer Nature B.V,SpringerOpen