Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Stop the leak!: Mitigating potential exposure of aerosolized COVID-19 during laparoscopic surgery
by
Uecker, John M
, Ahmad, Naser
, Gilkey, Mitchell
, Fagerberg Austin
, Cohen, Alexander
, Alembeigi Farshid
, Idelson Christopher R
in
Coronaviruses
/ COVID-19
/ Laparoscopy
/ Surgery
2021
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Stop the leak!: Mitigating potential exposure of aerosolized COVID-19 during laparoscopic surgery
by
Uecker, John M
, Ahmad, Naser
, Gilkey, Mitchell
, Fagerberg Austin
, Cohen, Alexander
, Alembeigi Farshid
, Idelson Christopher R
in
Coronaviruses
/ COVID-19
/ Laparoscopy
/ Surgery
2021
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Stop the leak!: Mitigating potential exposure of aerosolized COVID-19 during laparoscopic surgery
Journal Article
Stop the leak!: Mitigating potential exposure of aerosolized COVID-19 during laparoscopic surgery
2021
Request Book From Autostore
and Choose the Collection Method
Overview
BackgroundViral particles have been shown to aerosolize into insufflated gas during laparoscopic surgery. In the operating room, this potentially exposes personnel to aerosolized viruses as well as carcinogens. In light of circumstances surrounding COVID-19 and a concern for the safety of healthcare professionals, our study seeks to quantify the volumes of gas leaked from dynamic interactions between laparoscopic instruments and the trocar port to better understand potential exposure to surgically aerosolized particles.MethodsA custom setup was constructed to simulate an insufflated laparoscopic surgical cavity. Two surgical instrument use scenarios were examined to observe and quantify opportunities for insufflation gas leakage. Both scenarios considered multiple configurations of instrument and trocar port sizes/dimensions: (1) the full insertion and full removal of a laparoscopic instrument from the port and (2) the movement of the scope within the port, recognized as “dynamic interaction”, which occurs nearly 100% of the time over the course of any procedure.ResultsFor a 5 mm instrument in a 5 mm trocar, the average volume of gas leaked during dynamic interaction and full insertion/removal scenarios were 43.67 and 25.97 mL of gas, respectively. Volume of gas leaked for a 5 mm instrument in a 12 mm port averaged 41.32 mL and 29.47 for dynamic interaction vs. instrument insertion and removal. Similar patterns were shown with a 10 mm instrument in 12 mm port, with 55.68 mL for the dynamic interaction and 58.59 for the instrument insertion/removal.ConclusionsDynamic interactions and insertion/removal events between laparoscopic instruments and ports appear to contribute to consistent leakage of insufflated gas into the OR. Any measures possible taken to reduce OR gas leakage should be considered in light of the current COVID-19 pandemic. Minimizing laparoscope and instrument removal and replacement would be one strategy to mitigate gas leakage during laparoscopic surgery.
Publisher
Springer Nature B.V
Subject
This website uses cookies to ensure you get the best experience on our website.