Robust Non-Contact Monitoring of Respiratory Rate using a Depth Camera
by
Addison, Paul S
, Borg, Ulf R
, Antunes, André
, Montgomery, Dean
, Smit, Philip
in
Algorithms
/ Cameras
/ Monitoring
/ Respiratory rate
/ Telemedicine
/ Torso
2023
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Robust Non-Contact Monitoring of Respiratory Rate using a Depth Camera
by
Addison, Paul S
, Borg, Ulf R
, Antunes, André
, Montgomery, Dean
, Smit, Philip
in
Algorithms
/ Cameras
/ Monitoring
/ Respiratory rate
/ Telemedicine
/ Torso
2023
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Robust Non-Contact Monitoring of Respiratory Rate using a Depth Camera
Journal Article
Robust Non-Contact Monitoring of Respiratory Rate using a Depth Camera
2023
Request Book From Autostore
and Choose the Collection Method
Overview
PurposeRespiratory rate (RR) is one of the most common vital signs with numerous clinical uses. It is an important indicator of acute illness and a significant change in RR is often an early indication of a potentially serious complication or clinical event such as respiratory tract infection, respiratory failure and cardiac arrest. Early identification of changes in RR allows for prompt intervention, whereas failing to detect a change may result in poor patient outcomes. Here, we report on the performance of a depth-sensing camera system for the continuous non-contact ‘touchless’ monitoring of Respiratory Rate.MethodsSeven healthy subjects undertook a range of breathing rates from 4 to 40 breaths-per-minute (breaths/min). These were set rates of 4, 5, 6, 8, 10, 15, 20, 25, 30, 35 and 40 breaths/min. In total, 553 separate respiratory rate recordings were captured across a range of conditions including body posture, position within the bed, lighting levels and bed coverings. Depth information was acquired from the scene using an Intel D415 RealSenseTM camera. This data was processed in real-time to extract depth changes within the subject’s torso region corresponding to respiratory activity. A respiratory rate RRdepth was calculated using our latest algorithm and output once-per-second from the device and compared to a reference.ResultsAn overall RMSD accuracy of 0.69 breaths/min with a corresponding bias of -0.034 was achieved across the target RR range of 4–40 breaths/min. Bland-Altman analysis revealed limits of agreement of -1.42 to 1.36 breaths/min. Three separate sub-ranges of low, normal and high rates, corresponding to < 12, 12–20, > 20 breaths/min, were also examined separately and each found to demonstrate RMSD accuracies of less than one breath-per-minute.ConclusionsWe have demonstrated high accuracy in performance for respiratory rate based on a depth camera system. We have shown the ability to perform well at both high and low rates which are clinically important.