MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Measurement of Acute Intraocular Pressure Elevation Immediately After Intravitreal Anti-VEGF Injection and Analysis of Prefilled Syringe Accuracy
Measurement of Acute Intraocular Pressure Elevation Immediately After Intravitreal Anti-VEGF Injection and Analysis of Prefilled Syringe Accuracy
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Measurement of Acute Intraocular Pressure Elevation Immediately After Intravitreal Anti-VEGF Injection and Analysis of Prefilled Syringe Accuracy
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Measurement of Acute Intraocular Pressure Elevation Immediately After Intravitreal Anti-VEGF Injection and Analysis of Prefilled Syringe Accuracy
Measurement of Acute Intraocular Pressure Elevation Immediately After Intravitreal Anti-VEGF Injection and Analysis of Prefilled Syringe Accuracy

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Measurement of Acute Intraocular Pressure Elevation Immediately After Intravitreal Anti-VEGF Injection and Analysis of Prefilled Syringe Accuracy
Measurement of Acute Intraocular Pressure Elevation Immediately After Intravitreal Anti-VEGF Injection and Analysis of Prefilled Syringe Accuracy
Journal Article

Measurement of Acute Intraocular Pressure Elevation Immediately After Intravitreal Anti-VEGF Injection and Analysis of Prefilled Syringe Accuracy

2026
Request Book From Autostore and Choose the Collection Method
Overview
To compare and evaluate, across different agents, the risk of intraocular pressure (IOP) elevation after anti-VEGF therapy and the accuracy of prefilled syringes. Total of 175 eyes treated with anti-VEGF drugs were enrolled for this study. An accuracy evaluation of the prefilled syringes was conducted involving 25 participants, comprising 17 physicians and 8 nurses. The anti-VEGF agents including aflibercept 2 mg, aflibercept 8 mg, brolucizumab, faricimab, and ranibizumab-BS were assessed. IOP was measured before, and at 1 and 15 minutes after intravitreal injection, and analyzed separately for each drug. Furthermore, prefilled syringes of aflibercept 2 mg, brolucizumab, and ranibizumab-BS, as well as 1-mL syringes filled with saline solution, were equipped with 30-gauge needles, followed by careful removal of air. The weight of the saline discharged according to the scale marking was measured using an electronic balance. At 1 min after intravitreal injection, the IOP was highest in the aflibercept 2 mg group, with a mean value of 52.8 mmHg. A mild inverse correlation was observed between axial length and IOP elevation at 1 min post-injection, suggesting that eyes with longer axial length exhibited less pronounced IOP increases. In the syringe accuracy analysis, the prefilled syringe of aflibercept 2 mg expelled a significantly larger volume, with a mean of approximately 0.076 mL, compared to other prefilled syringes. Intravitreal injection using the aflibercept 2 mg prefilled syringe may deliver approximately 1.5 times the intended volume into the eye. This may raise safety concerns, such as the risk of transient vision loss due to marked immediate IOP elevation, and may also affect clinical outcomes and the validity of clinical trials.