MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Viscoelastic Hemostatic Assays are Associated With Mortality and Blood Transfusion in a Multicenter Cohort
Viscoelastic Hemostatic Assays are Associated With Mortality and Blood Transfusion in a Multicenter Cohort
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Viscoelastic Hemostatic Assays are Associated With Mortality and Blood Transfusion in a Multicenter Cohort
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Viscoelastic Hemostatic Assays are Associated With Mortality and Blood Transfusion in a Multicenter Cohort
Viscoelastic Hemostatic Assays are Associated With Mortality and Blood Transfusion in a Multicenter Cohort

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Viscoelastic Hemostatic Assays are Associated With Mortality and Blood Transfusion in a Multicenter Cohort
Viscoelastic Hemostatic Assays are Associated With Mortality and Blood Transfusion in a Multicenter Cohort
Journal Article

Viscoelastic Hemostatic Assays are Associated With Mortality and Blood Transfusion in a Multicenter Cohort

2025
Request Book From Autostore and Choose the Collection Method
Overview
Trauma-induced coagulopathy (TIC) carries significant risks, including increased mortality. Traditional TIC definitions rely on laboratories that result slowly and do not highlight therapeutic targets. We hypothesized that a TIC score, based on thromboelastography (TEG) and rotational thromboelastometry (ROTEM), collectively termed viscoelastic hemostatic assays, is associated with in-hospital mortality and packed red blood cell (pRBC) transfusion. This retrospective cohort study used a database of adult patients undergoing institutional massive transfusion at seven level 1 trauma centers (2013-2018). A “TIC score” was developed, with 1 point assigned for abnormal TEG R-time (≥ 9 min) or ROTEM clot time (≥ 80 sec), ɑ-angle (< 65o), or maximum amplitude (< 55 mm). TIC+ patients (TIC score 1-3) were compared with TIC− patients (TIC score 0). TIC Score composition and abnormal cutoff values were adjusted to investigate optimal weighting and thresholds. Multiple logistic and negative binomial regression was used to control confounders while evaluating the association between abnormal TIC values, in-hospital mortality, and 24-hour pRBC transfusion. Of 1499 patients in the final analysis, 591 (39.4%) were TIC+. Each 1-point increase in TIC score was associated with a 53% increase in the odds of mortality (odds ratio [OR], 1.53, 95% CI, 1.33-1.76, P < .001) and a 25% increase in pRBC transfusion volumes (incidence rate ratio, 1.25, 95% CI, 1.16-1.34, P < .001). Abnormal maximum amplitude was associated with both mortality (OR 1.50, 95% CI, 1.03-2.19, P = .034) and pRBC transfusion volumes (P < .001), whereas abnormal ɑ-angle was associated with mortality (OR, 1.59, 95% CI, 1.09-2.32, P = .015). The unequal weighting of TIC score components and adjustments to normal/abnormal cutoff thresholds were maintained but did not improve the model’s predictive power. A viscoelastic hemostatic assay-based TIC score is independently associated with mortality and pRBC transfusion volumes. This association persists with unequal weighting and adjustment of normal/abnormal cutoff thresholds of TEG components.