Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Comparison of accuracy and precision between multipoint calibration, single point calibration, and relative quantification for targeted metabolomic analysis
by
Khamis, Mona M
, El-Aneed, Anas
, Klemm, Nancy
, Adamko, Darryl J
in
Biomarkers
/ Calibration
/ Ethanolamine
/ Metabolites
/ Metabolomics
/ Reagents
/ Serine
/ Spectrometry
/ Urine
/ Workload
/ Workloads
2018
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Comparison of accuracy and precision between multipoint calibration, single point calibration, and relative quantification for targeted metabolomic analysis
by
Khamis, Mona M
, El-Aneed, Anas
, Klemm, Nancy
, Adamko, Darryl J
in
Biomarkers
/ Calibration
/ Ethanolamine
/ Metabolites
/ Metabolomics
/ Reagents
/ Serine
/ Spectrometry
/ Urine
/ Workload
/ Workloads
2018
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Comparison of accuracy and precision between multipoint calibration, single point calibration, and relative quantification for targeted metabolomic analysis
by
Khamis, Mona M
, El-Aneed, Anas
, Klemm, Nancy
, Adamko, Darryl J
in
Biomarkers
/ Calibration
/ Ethanolamine
/ Metabolites
/ Metabolomics
/ Reagents
/ Serine
/ Spectrometry
/ Urine
/ Workload
/ Workloads
2018
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Comparison of accuracy and precision between multipoint calibration, single point calibration, and relative quantification for targeted metabolomic analysis
Journal Article
Comparison of accuracy and precision between multipoint calibration, single point calibration, and relative quantification for targeted metabolomic analysis
2018
Request Book From Autostore
and Choose the Collection Method
Overview
Targeted metabolomics requires accurate and precise quantification of candidate biomarkers, often through tandem mass spectrometric (MS/MS) analysis. Differential isotope labeling (DIL) improves mass spectrometric (MS) analysis in metabolomics by derivatizing metabolites with two isotopic forms of the same reagent. Despite its advantages, DIL-liquid chromatographic (LC)-MS/MS can result in substantial increase in workload when fully validated quantitative methods are required. To decrease the workload, we hypothesized that single point calibration or relative quantification could be used as alternative methods. Either approach will result in significant saving in resources and time. To test our hypothesis, six urinary metabolites were selected as model compounds. Urine samples were analyzed using a fully validated multipoint dansyl chloride-DIL-LC-MS/MS method. Samples were reprocessed using single point calibration and relative quantification modes. Our results demonstrated that the performance of single point calibration or relative quantification was inferior, for some metabolites, to multipoint calibration. The lower limit of quantification failed in the quantification of ethanolamine in most of participant samples using single point calibration. In addition, its precision was not acceptable in one participant during serine and ethanolamine quantification. On the other hand, relative quantification resulted in the least accurate data. In fact, none of the data generated from relative quantification for serine was comparable to that obtained from multipoint calibration. Finally, while single point calibration showed an overall acceptable performance for the majority of the model compounds, we cannot extrapolate the findings to other metabolites within the same analytical run. Analysts are advised to assess accuracy and precision for each metabolite in which single point calibration is the intended quantification mean.
MBRLCatalogueRelatedBooks
This website uses cookies to ensure you get the best experience on our website.