MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Evaluation of Bone Density for Primary Implant Stability Using a Newly Designed Drill: An In Vitro Study on Polyurethane Bone Blocks
Evaluation of Bone Density for Primary Implant Stability Using a Newly Designed Drill: An In Vitro Study on Polyurethane Bone Blocks
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Evaluation of Bone Density for Primary Implant Stability Using a Newly Designed Drill: An In Vitro Study on Polyurethane Bone Blocks
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Evaluation of Bone Density for Primary Implant Stability Using a Newly Designed Drill: An In Vitro Study on Polyurethane Bone Blocks
Evaluation of Bone Density for Primary Implant Stability Using a Newly Designed Drill: An In Vitro Study on Polyurethane Bone Blocks

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Evaluation of Bone Density for Primary Implant Stability Using a Newly Designed Drill: An In Vitro Study on Polyurethane Bone Blocks
Evaluation of Bone Density for Primary Implant Stability Using a Newly Designed Drill: An In Vitro Study on Polyurethane Bone Blocks
Journal Article

Evaluation of Bone Density for Primary Implant Stability Using a Newly Designed Drill: An In Vitro Study on Polyurethane Bone Blocks

2024
Request Book From Autostore and Choose the Collection Method
Overview
Objectives Bone density is an important factor for long‐term implant success. Peri‐implant bone density evaluation before implant placement can be useful for treatment planning, such as the selection of proper implant size or drilling protocol in each case. In this study, we aimed to establish an objective intraoperative bone density evaluation method by measuring the drilling torque value using a newly designed density measurement drill. Materials and Methods Drilling torque value measurement was performed intraoperatively using three types of drills; two previously reported drills and a newly designed drill as a density measurement drill. Polyurethane bone blocks of different densities (D1–D4) were used in this experiment. After the measurement, implants were inserted based on the scheduled plan, and insertion torque (IT) and implant stability quotient (ISQ) were measured to assess primary implant stability. Results The drilling torque value increased with the bone blocks' density, and there were significant differences among different densities in all groups (p < 0.05). The drilling torque value showed a positive correlation with IT in all groups (p < 0.05). In addition, the drilling torque value increased with the increase in ISQ in all groups. Conclusions Within the limitations of this study, a newly designed density measurement drill was able to classify D1–D4 in polyurethane bone blocks despite its narrow diameter, and an objective intraoperative bone evaluation can be achieved. An intraoperative assessment of the drilling torque value can predict primary implant stability and provide valuable information for intraoperative treatment planning, such as undersized drilling protocol and implant size change.