Breast Cancer Detection Using Low-Frequency Bioimpedance Device
by
Mansouri, Sofiene
, Ben Azouz, Marwa
, Alhadidi, Tareq
in
Aqueous solutions
/ Biomedical engineering
/ Breast cancer
/ breast cancer detection
/ Cancer diagnosis
/ Chlorides
/ Electric currents
/ Electric properties
/ electrical bioimpedance
/ Electrical conductivity
/ Electrodes
/ FPGA Virtex-5 LX30
/ Invasiveness
/ LabVIEW FPGA
/ Mammography
/ NI PXI-7841R
/ Original Research
/ Physiological aspects
/ Tumors
2020
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Breast Cancer Detection Using Low-Frequency Bioimpedance Device
by
Mansouri, Sofiene
, Ben Azouz, Marwa
, Alhadidi, Tareq
in
Aqueous solutions
/ Biomedical engineering
/ Breast cancer
/ breast cancer detection
/ Cancer diagnosis
/ Chlorides
/ Electric currents
/ Electric properties
/ electrical bioimpedance
/ Electrical conductivity
/ Electrodes
/ FPGA Virtex-5 LX30
/ Invasiveness
/ LabVIEW FPGA
/ Mammography
/ NI PXI-7841R
/ Original Research
/ Physiological aspects
/ Tumors
2020
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Breast Cancer Detection Using Low-Frequency Bioimpedance Device
by
Mansouri, Sofiene
, Ben Azouz, Marwa
, Alhadidi, Tareq
in
Aqueous solutions
/ Biomedical engineering
/ Breast cancer
/ breast cancer detection
/ Cancer diagnosis
/ Chlorides
/ Electric currents
/ Electric properties
/ electrical bioimpedance
/ Electrical conductivity
/ Electrodes
/ FPGA Virtex-5 LX30
/ Invasiveness
/ LabVIEW FPGA
/ Mammography
/ NI PXI-7841R
/ Original Research
/ Physiological aspects
/ Tumors
2020
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Breast Cancer Detection Using Low-Frequency Bioimpedance Device
Journal Article
Breast Cancer Detection Using Low-Frequency Bioimpedance Device
2020
Request Book From Autostore
and Choose the Collection Method
Overview
Early detection of breast cancer saves lives. Existing detecting techniques are invasive. Electrical bioimpedance is a noninvasive technique and has a high diagnostic potential.
An impedance value different from the normal can predict a physiological abnormality. The idea is to use a designed bioimpedance device to early detect breast cancer. A low-frequency current (1 kHz, 0.9 mA) is injected to each breast to measure the extracellular resistances. The resistances of the two breasts are then measured, and if there is a significant difference, warning is displayed. The performance was tested on a set of reference resistors, and the validation was done in vitro on (Na+Cl-) solutions and in vivo on a group of forty volunteer women.
The results confirm that the electrical conductivity of an ionic solution is proportional to its concentration. The concentration and the resistance are strongly correlated (correlation coefficient of 0.97). The accuracy and the repeatability of the measures were satisfactory. Early detection means that we can detect small extracellular concentration variations into the breast (from 0.6 g/l). In vivo measurements made it possible to set the threshold at 50 ohm. If the difference between the two measured breast resistances is greater than this threshold, we advise the patient to consult a doctor promptly.
The difference between measured resistances of the right and left breast is a pertinent parameter to early detect the presence of a cancer. The lowest resistance value (RR or RL) can provide information on the breast affected by the cancer (right or left). Various improvements in the system are possible but already the results are encouraging. In the future, this system could be integrated into a bra.