Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Monte Carlo simulation of the Varian TrueBeam flattened-filtered beams using a surrogate geometry in PRIMO
by
Sempau, Josep
, Brualla, Lorenzo
, Rodriguez, Miguel
in
Analysis
/ Approximation
/ Biomedical and Life Sciences
/ Biomedicine
/ Cancer Research
/ Computer Simulation
/ Energy
/ Flattening
/ Gamma Rays
/ Geometry
/ Humans
/ Imaging
/ Linear accelerator
/ Linear accelerators
/ Machinery
/ Magneto-electric machines
/ Medical research
/ Medicine, Experimental
/ Methods
/ Monte Carlo
/ Monte Carlo Method
/ Monte Carlo simulation
/ Oncology
/ Patient outcomes
/ Phase space
/ PRIMO
/ Radiation
/ Radiation transport
/ Radiology
/ Radiotherapy
/ Simulation methods
/ Transcription Factors
2024
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Monte Carlo simulation of the Varian TrueBeam flattened-filtered beams using a surrogate geometry in PRIMO
by
Sempau, Josep
, Brualla, Lorenzo
, Rodriguez, Miguel
in
Analysis
/ Approximation
/ Biomedical and Life Sciences
/ Biomedicine
/ Cancer Research
/ Computer Simulation
/ Energy
/ Flattening
/ Gamma Rays
/ Geometry
/ Humans
/ Imaging
/ Linear accelerator
/ Linear accelerators
/ Machinery
/ Magneto-electric machines
/ Medical research
/ Medicine, Experimental
/ Methods
/ Monte Carlo
/ Monte Carlo Method
/ Monte Carlo simulation
/ Oncology
/ Patient outcomes
/ Phase space
/ PRIMO
/ Radiation
/ Radiation transport
/ Radiology
/ Radiotherapy
/ Simulation methods
/ Transcription Factors
2024
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Monte Carlo simulation of the Varian TrueBeam flattened-filtered beams using a surrogate geometry in PRIMO
by
Sempau, Josep
, Brualla, Lorenzo
, Rodriguez, Miguel
in
Analysis
/ Approximation
/ Biomedical and Life Sciences
/ Biomedicine
/ Cancer Research
/ Computer Simulation
/ Energy
/ Flattening
/ Gamma Rays
/ Geometry
/ Humans
/ Imaging
/ Linear accelerator
/ Linear accelerators
/ Machinery
/ Magneto-electric machines
/ Medical research
/ Medicine, Experimental
/ Methods
/ Monte Carlo
/ Monte Carlo Method
/ Monte Carlo simulation
/ Oncology
/ Patient outcomes
/ Phase space
/ PRIMO
/ Radiation
/ Radiation transport
/ Radiology
/ Radiotherapy
/ Simulation methods
/ Transcription Factors
2024
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Monte Carlo simulation of the Varian TrueBeam flattened-filtered beams using a surrogate geometry in PRIMO
Journal Article
Monte Carlo simulation of the Varian TrueBeam flattened-filtered beams using a surrogate geometry in PRIMO
2024
Request Book From Autostore
and Choose the Collection Method
Overview
Background
Monte Carlo simulation of radiation transport for medical linear accelerators (linacs) requires accurate knowledge of the geometrical description of the linac head. Since the geometry of Varian TrueBeam machines has not been disclosed, the manufacturer distributes phase-space files of the linac patient-independent part to allow researchers to compute absorbed dose distributions using the Monte Carlo method. This approach limits the possibility of achieving an arbitrarily small statistical uncertainty. This work investigates the use of the geometry of the Varian Clinac 2100, which is included in the Monte Carlo system PRIMO, as a surrogate.
Methods
Energy, radial and angular distributions extracted from the TrueBeam phase space files published by the manufacturer and from phase spaces tallied with PRIMO for the Clinac 2100 were compared for the 6, 8, 10 and 15 MV flattened-filtered beams. Dose distributions in water computed for the two sets of PSFs were compared with the Varian Representative Beam Data (RBD) for square fields with sides ranging from 3 to 30 cm. Output factors were calculated for square fields with sides ranging from 2 to 40 cm.
Results
Excellent agreement with the RBD was obtained for the simulations that employed the phase spaces distributed by Varian as well as for those that used the surrogate geometry, reaching in both cases Gamma (
2
%
, 2 mm) pass rates larger than
99
%
, except for the 15 MV surrogate. This result supports previous investigations that suggest a change in the material composition of the TrueBeam 15 MV flattening filter. In order to get the said agreement, PRIMO simulations were run using enlarged transport parameters to compensate the discrepancies between the actual and surrogate geometries.
Conclusions
This work sustains the claim that the simulation of the 6, 8 and 10 MV flattening-filtered beams of the TrueBeam linac can be performed using the Clinac 2100 model of PRIMO without significant loss of accuracy.
This website uses cookies to ensure you get the best experience on our website.