MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Influence of air gap under bolus in the dosimetry of a clinical 6 MV photon beam
Influence of air gap under bolus in the dosimetry of a clinical 6 MV photon beam
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Influence of air gap under bolus in the dosimetry of a clinical 6 MV photon beam
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Influence of air gap under bolus in the dosimetry of a clinical 6 MV photon beam
Influence of air gap under bolus in the dosimetry of a clinical 6 MV photon beam

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Influence of air gap under bolus in the dosimetry of a clinical 6 MV photon beam
Influence of air gap under bolus in the dosimetry of a clinical 6 MV photon beam
Journal Article

Influence of air gap under bolus in the dosimetry of a clinical 6 MV photon beam

2020
Request Book From Autostore and Choose the Collection Method
Overview
Aim: In some situations of radiotherapy treatments requiring application of tissue-equivalent bolus material (e.g., gel bolus), due to material's rigid/semi-rigid nature, undesirable air gaps may occur beneath it because of irregularity of body surface. The purpose of this study was to evaluate the dosimetric parameters such as surface dose (Ds), depth of dose maximum (dmax), and depth dose along central axis derived from the percentage depth dose (PDD) curve of a 6 MV clinical photon beam in the presence of air gaps between the gel bolus and the treatment surface. Materials and Methods: A bolus holder was designed to hold the gel bolus sheet to create an air gap between the bolus and the radiation field analyzer's (RFA-300) water surface. PDD curves were taken for field sizes of 5 cm × 5 cm, 10 cm × 10 cm, 15 cm × 15 cm, 20 cm × 20 cm, and 25 cm × 25 cm, with different thicknesses of gel bolus (0.5, 1.0, and 1.5 cm) and air gap (from 0.0 to 3.0 cm), using a compact ionization chamber (CC13) with RFA-300 keeping 100 cm source-to-surface (water) distance. The dosimetric parameters, for example, \"Ds,\" \"dmax,\" and difference of PDD (maximum air gap vs. nil air gap), were analyzed from the obtained PDD curves. Results: Compared to ideal conditions of full contact of bolus with water surface, it has been found that there is a reduction in \"Ds\" ranging from 14.8% to 3.2%, 14.9% to 1.1%, and 12.6% to 0.7% with the increase of field size for 0.5, 1.0, and 1.5 cm thickness of gel boluses, respectively, for maximum air gap. The \"dmax\" shows a trend of moving away from the treatment surface, and the maximum shift was observed for smaller field size with thicker bolus and greater air gap. The effect of air gap on PDD is minimal (≤1%) beyond 0.4 cm depth for all bolus thicknesses and field sizes except for 5 cm × 5 cm with 1.5 cm bolus thickness. Conclusions: The measured data can be used to predict the probable effect on therapeutic outcome due to the presence of inevitable air gaps between the bolus and the treatment surface.
Publisher
Wolters Kluwer India Pvt. Ltd,Medknow Publications and Media Pvt. Ltd,Medknow Publications & Media Pvt. Ltd,Wolters Kluwer - Medknow,Wolters Kluwer Medknow Publications