Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
A novel partial volume correction method for accurate quantification of 18F flortaucipir in the hippocampus
by
Wolters, Emma E
, Lammertsma, Adriaan A
, Bart N M van Berckel
, Ossenkoppele, Rik
, Chris W J van der Weijden
, Windhorst, Albert D
, Schwarte, Lothar
, Yaqub, Maqsood
, Golla, Sandeep S V
, Boellaard, Ronald
, Timmers, Tessa
, Barkhof, Frederik
, Scheltens, Philip
, Schuit, Robert C
in
Hippocampus
/ Nuclear medicine
/ Positron emission
/ Tomography
2018
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
A novel partial volume correction method for accurate quantification of 18F flortaucipir in the hippocampus
by
Wolters, Emma E
, Lammertsma, Adriaan A
, Bart N M van Berckel
, Ossenkoppele, Rik
, Chris W J van der Weijden
, Windhorst, Albert D
, Schwarte, Lothar
, Yaqub, Maqsood
, Golla, Sandeep S V
, Boellaard, Ronald
, Timmers, Tessa
, Barkhof, Frederik
, Scheltens, Philip
, Schuit, Robert C
in
Hippocampus
/ Nuclear medicine
/ Positron emission
/ Tomography
2018
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
A novel partial volume correction method for accurate quantification of 18F flortaucipir in the hippocampus
by
Wolters, Emma E
, Lammertsma, Adriaan A
, Bart N M van Berckel
, Ossenkoppele, Rik
, Chris W J van der Weijden
, Windhorst, Albert D
, Schwarte, Lothar
, Yaqub, Maqsood
, Golla, Sandeep S V
, Boellaard, Ronald
, Timmers, Tessa
, Barkhof, Frederik
, Scheltens, Philip
, Schuit, Robert C
in
Hippocampus
/ Nuclear medicine
/ Positron emission
/ Tomography
2018
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
A novel partial volume correction method for accurate quantification of 18F flortaucipir in the hippocampus
Journal Article
A novel partial volume correction method for accurate quantification of 18F flortaucipir in the hippocampus
2018
Request Book From Autostore
and Choose the Collection Method
Overview
BackgroundOff-target binding in the choroid plexus (CP) may cause spill-in of the tau PET tracer [18F] flortaucipir into the adjacent hippocampus region. The impact of this spill-in on hippocampal uptake was assessed using a novel partial volume correction method (PVC).MethodsPVC was performed on 20 [18F] flortaucipir dynamic PET scans (10 probable AD and 10 controls). Volumes of interest (VOIs) were defined for both hippocampus and CP. The correlation between hippocampal and CP distribution volume (VT), with and without PVC, was determined. Both anatomically defined and eroded VOIs were used.ResultsFor controls, the correlation between hippocampal and CP VT was significantly reduced after using PVC along with an eroded VOI (r2 = 0.59, slope = 0.80 versus r2 = 0.15, slope = 0.15; difference: p < 0.05). The same was true for AD patients (p < 0.05).ConclusionPVC together with an optimized hippocampal VOI resulted in effective reduction of CP spill-in and improved accuracy of hippocampal VT.
Publisher
Springer Nature B.V
Subject
This website uses cookies to ensure you get the best experience on our website.