Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Can the intermittent low-speed function of left ventricular assist device prevent aortic insufficiency?
by
Sawa, Yoshiki
, Fukushima, Norihide
, Kohno, Hiroki
, Saiki, Yoshikatsu
, Matsumiya, Goro
, Ono, Minoru
, Shiose, Akira
in
Aorta
/ Aortic valve
/ Cardiomyopathy
/ Continuous flow
/ Correlation
/ Data collection
/ Ejection fraction
/ Extracorporeal membrane oxygenation
/ Heart failure
/ Heart surgery
/ Heart transplantation
/ Heart transplants
/ Heart valves
/ Implantation
/ Low speed
/ Variables
/ Ventricle
/ Ventricular assist devices
2021
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Can the intermittent low-speed function of left ventricular assist device prevent aortic insufficiency?
by
Sawa, Yoshiki
, Fukushima, Norihide
, Kohno, Hiroki
, Saiki, Yoshikatsu
, Matsumiya, Goro
, Ono, Minoru
, Shiose, Akira
in
Aorta
/ Aortic valve
/ Cardiomyopathy
/ Continuous flow
/ Correlation
/ Data collection
/ Ejection fraction
/ Extracorporeal membrane oxygenation
/ Heart failure
/ Heart surgery
/ Heart transplantation
/ Heart transplants
/ Heart valves
/ Implantation
/ Low speed
/ Variables
/ Ventricle
/ Ventricular assist devices
2021
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Can the intermittent low-speed function of left ventricular assist device prevent aortic insufficiency?
by
Sawa, Yoshiki
, Fukushima, Norihide
, Kohno, Hiroki
, Saiki, Yoshikatsu
, Matsumiya, Goro
, Ono, Minoru
, Shiose, Akira
in
Aorta
/ Aortic valve
/ Cardiomyopathy
/ Continuous flow
/ Correlation
/ Data collection
/ Ejection fraction
/ Extracorporeal membrane oxygenation
/ Heart failure
/ Heart surgery
/ Heart transplantation
/ Heart transplants
/ Heart valves
/ Implantation
/ Low speed
/ Variables
/ Ventricle
/ Ventricular assist devices
2021
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Can the intermittent low-speed function of left ventricular assist device prevent aortic insufficiency?
Journal Article
Can the intermittent low-speed function of left ventricular assist device prevent aortic insufficiency?
2021
Request Book From Autostore
and Choose the Collection Method
Overview
Aortic insufficiency (AI) is known to associate with a persistently closed aortic valve during continuous-flow ventricular assist device support. Some devices carry an intermittent low-speed (ILS) function, which facilitates aortic valve opening, but whether this function prevents AI is unknown. In this study, the Jarvik 2000 device, which is programmed to reduce the pump speed each minute for 8 s, was chosen to examine this potential effect. Prospectively collected data of 85 heart transplant-eligible Jarvik 2000 recipients who met the study criteria (no pre-existing AI and aortic valve surgery) were retrospectively analyzed for the incidence, correlating factors, and clinical outcomes of de novo AI. All data were provided by the Japanese Registry for Mechanically Assisted Circulatory Support. De novo AI occurred in 58 patients, 23 of whom developed at least moderate AI during a median support duration of 23.5 months. Freedom from moderate or greater AI was 84.4%, 66.1% and 60.2% at 1, 2 and 3 years, respectively. Multivariate analyses revealed that progressive AI was correlated with decreased pulse pressure after implantation (hazard ratio 1.060, 95% confidence interval 1.001–1.127, p = 0.045). No correlation was found for mortality or other adverse events, including stroke, bleeding, infection, pump failure, hemolysis, and readmission. The benefit of the Jarvik 2000′s current ILS mode against AI appears to be minimal. However, in this limited cohort where all recipients underwent implantation as a bridge to transplantation, the impact of de novo progressive AI on other clinical adversities was also minimal.
Publisher
Springer Nature B.V
Subject
MBRLCatalogueRelatedBooks
Related Items
Related Items
We currently cannot retrieve any items related to this title. Kindly check back at a later time.
This website uses cookies to ensure you get the best experience on our website.