MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Evaluator effect on the ultrasound measurement of subcutaneous fat deposition and loin eye area from weaning to slaughter lambs
Evaluator effect on the ultrasound measurement of subcutaneous fat deposition and loin eye area from weaning to slaughter lambs
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Evaluator effect on the ultrasound measurement of subcutaneous fat deposition and loin eye area from weaning to slaughter lambs
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Evaluator effect on the ultrasound measurement of subcutaneous fat deposition and loin eye area from weaning to slaughter lambs
Evaluator effect on the ultrasound measurement of subcutaneous fat deposition and loin eye area from weaning to slaughter lambs

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Evaluator effect on the ultrasound measurement of subcutaneous fat deposition and loin eye area from weaning to slaughter lambs
Evaluator effect on the ultrasound measurement of subcutaneous fat deposition and loin eye area from weaning to slaughter lambs
Journal Article

Evaluator effect on the ultrasound measurement of subcutaneous fat deposition and loin eye area from weaning to slaughter lambs

2021
Request Book From Autostore and Choose the Collection Method
Overview
Background and Aim: Ultrasound is a non-invasive technique that enables animal evaluation and body condition classification of animals. Although it is not difficult to obtain an image, the analysis of this image can influence results quality. This study aimed to evaluate the repeatability and reproducibility of the technician trained in image interpretation obtained using different ultrasound frequencies. Materials and Methods: Ninety-six lambs were used, ranging in weight from 15 to 40 kg. The images were captured using a linear probe of 13 cm, with a 3.5 megahertz (MHz) frequency and an acoustic couplant aid \"standoff\" or using a multifrequency transducer (6 and 8 MHz), on B mode, with a linear probe and 8.0 MHz frequency. All measurements were performed by the same technician, on the left side, between the 12th and 13th rib. Five different evaluators, at two different times, with aid of Image J software measured the loin eye area (LEA; only for images obtained with 3.5 MHz), Longissimus thoracis et lumborum depth (DLM), subcutaneous fat thickness (SFT), subcutaneous fat thickness plus skin (SFST), and skin thickness (ST). Results: For LEA, DLM, SFT, SFST, and ST, variation was observed (p<0.01) between evaluators; however, there was no difference (p>0.05) between the 2 times of evaluation. Images measurements obtained with a frequency of 8.0 MHz had better repeatability indices and reproducibility indices. Accordingly, the identity test demonstrated that measurements performed on images obtained using 3.5 or 8.0 MHz were not equivalent. Conclusion: Ultrasound image measurements obtained using an 8.0 MHz frequency were more accurate and precise. It is important to use only one evaluator or providing the simultaneous training for all evaluators.