Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Duty cycle of 33% increases cardiac output during cardiopulmonary resuscitation
by
Suh, Gil Joon
, Jung, Yoon Sun
, Shin, So Mi
, Ko, Jung-In
, Kwon, Woon Yong
, Kim, Taegyun
, Kim, Kyung Su
in
Animals
/ Arterial Pressure - physiology
/ Atrial Pressure - physiology
/ Biology and Life Sciences
/ Blood pressure
/ Capnography
/ Carbon cycle
/ Carbon dioxide
/ Carbon Dioxide - analysis
/ Carbon Dioxide - physiology
/ Cardiac arrhythmia
/ Cardiac output
/ Cardiac Output - physiology
/ Cardiopulmonary resuscitation
/ Cardiopulmonary Resuscitation - methods
/ Catheters
/ Cerebrovascular Circulation - physiology
/ Comparative analysis
/ CPR
/ Disease Models, Animal
/ Electric countershock
/ Emergency medical care
/ Engineering and Technology
/ Experiments
/ Fibrillation
/ Hardware reviews
/ Heart
/ Heart rate
/ Hemorrhagic shock
/ Laboratories
/ Male
/ Medical research
/ Medicine
/ Medicine and Health Sciences
/ Monitoring, Physiologic
/ Perfusion
/ Prospective Studies
/ Resuscitation
/ Statistics
/ Swine
/ Tidal Volume - physiology
/ Vecuronium
/ Ventilators
/ Ventricle
/ Ventricular fibrillation
/ Ventricular Fibrillation - physiopathology
/ Ventricular Fibrillation - therapy
/ Ventricular Fibrillation - veterinary
2020
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Duty cycle of 33% increases cardiac output during cardiopulmonary resuscitation
by
Suh, Gil Joon
, Jung, Yoon Sun
, Shin, So Mi
, Ko, Jung-In
, Kwon, Woon Yong
, Kim, Taegyun
, Kim, Kyung Su
in
Animals
/ Arterial Pressure - physiology
/ Atrial Pressure - physiology
/ Biology and Life Sciences
/ Blood pressure
/ Capnography
/ Carbon cycle
/ Carbon dioxide
/ Carbon Dioxide - analysis
/ Carbon Dioxide - physiology
/ Cardiac arrhythmia
/ Cardiac output
/ Cardiac Output - physiology
/ Cardiopulmonary resuscitation
/ Cardiopulmonary Resuscitation - methods
/ Catheters
/ Cerebrovascular Circulation - physiology
/ Comparative analysis
/ CPR
/ Disease Models, Animal
/ Electric countershock
/ Emergency medical care
/ Engineering and Technology
/ Experiments
/ Fibrillation
/ Hardware reviews
/ Heart
/ Heart rate
/ Hemorrhagic shock
/ Laboratories
/ Male
/ Medical research
/ Medicine
/ Medicine and Health Sciences
/ Monitoring, Physiologic
/ Perfusion
/ Prospective Studies
/ Resuscitation
/ Statistics
/ Swine
/ Tidal Volume - physiology
/ Vecuronium
/ Ventilators
/ Ventricle
/ Ventricular fibrillation
/ Ventricular Fibrillation - physiopathology
/ Ventricular Fibrillation - therapy
/ Ventricular Fibrillation - veterinary
2020
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Duty cycle of 33% increases cardiac output during cardiopulmonary resuscitation
by
Suh, Gil Joon
, Jung, Yoon Sun
, Shin, So Mi
, Ko, Jung-In
, Kwon, Woon Yong
, Kim, Taegyun
, Kim, Kyung Su
in
Animals
/ Arterial Pressure - physiology
/ Atrial Pressure - physiology
/ Biology and Life Sciences
/ Blood pressure
/ Capnography
/ Carbon cycle
/ Carbon dioxide
/ Carbon Dioxide - analysis
/ Carbon Dioxide - physiology
/ Cardiac arrhythmia
/ Cardiac output
/ Cardiac Output - physiology
/ Cardiopulmonary resuscitation
/ Cardiopulmonary Resuscitation - methods
/ Catheters
/ Cerebrovascular Circulation - physiology
/ Comparative analysis
/ CPR
/ Disease Models, Animal
/ Electric countershock
/ Emergency medical care
/ Engineering and Technology
/ Experiments
/ Fibrillation
/ Hardware reviews
/ Heart
/ Heart rate
/ Hemorrhagic shock
/ Laboratories
/ Male
/ Medical research
/ Medicine
/ Medicine and Health Sciences
/ Monitoring, Physiologic
/ Perfusion
/ Prospective Studies
/ Resuscitation
/ Statistics
/ Swine
/ Tidal Volume - physiology
/ Vecuronium
/ Ventilators
/ Ventricle
/ Ventricular fibrillation
/ Ventricular Fibrillation - physiopathology
/ Ventricular Fibrillation - therapy
/ Ventricular Fibrillation - veterinary
2020
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Duty cycle of 33% increases cardiac output during cardiopulmonary resuscitation
Journal Article
Duty cycle of 33% increases cardiac output during cardiopulmonary resuscitation
2020
Request Book From Autostore
and Choose the Collection Method
Overview
The aim of this study was to investigate whether 33% duty cycle increases end-tidal carbon dioxide (ETCO2) level, a surrogate measurement for cardiac output during cardiopulmonary resuscitation (CPR), compared with 50% duty cycle.
Six pigs were randomly assigned to the DC33 or DC50 group. After 3 min of induced ventricular fibrillation (VF), CPR was performed for 5 min with 33% duty cycle (DC33 group) or with 50% duty cycle (DC50 group) (phase I). Defibrillation was delivered until return of spontaneous circulation (ROSC) thereafter. After 30 min of stabilization, the animals were re-assigned to the opposite groups. VF was induced again, and CPR was performed (phase II). The primary outcome was ETCO2 during CPR, and the secondary outcomes were coronary perfusion pressure (CPP), systolic arterial pressure (SAP), diastolic arterial pressure (DAP), and right atrial pressure (RAP).
Mean ETCO2 was higher in the DC33 group compared with the DC50 group (22.5 mmHg vs 21.5 mmHg, P = 0.018). In a linear mixed model, 33% duty cycle increased ETCO2 by 1.0 mmHg compared with 50% duty cycle (P < 0.001). ETCO2 increased over time in the DC33 group [0.6 mmHg/min] while ETCO2 decreased in the DC50 group [-0.6 mmHg/min] (P < 0.001). Duty cycle of 33% increased SAP (6.0 mmHg, P < 0.001), DAP (8.9 mmHg, P < 0.001) RAP (2.6 mmHg, P < 0.001) and CPP (4.7 mmHg, P < 0.001) compared with the duty cycle of 50%.
Duty cycle of 33% increased ETCO2, a surrogate measurement for cardiac output during CPR, compared with duty cycle of 50%. Moreover, ETCO2 increased over time during CPR with 33% duty cycle while ETCO2 decreased with 50% duty cycle.
Publisher
Public Library of Science,Public Library of Science (PLoS)
Subject
/ Arterial Pressure - physiology
/ Atrial Pressure - physiology
/ Cardiopulmonary resuscitation
/ Cardiopulmonary Resuscitation - methods
/ Cerebrovascular Circulation - physiology
/ CPR
/ Heart
/ Male
/ Medicine
/ Medicine and Health Sciences
/ Swine
/ Ventricular Fibrillation - physiopathology
MBRLCatalogueRelatedBooks
Related Items
Related Items
This website uses cookies to ensure you get the best experience on our website.