A multi-center inter-manufacturer study of the temporal stability of phase-contrast velocity mapping background offset errors
by
Gatehouse, Peter D
, Kilner, Philip J
, Bloch, Karin Markenroth
, Rolf, Marijn P
, Hofman, Mark BM
, Graves, Martin J
, Firmin, David N
in
Acquisitions
/ Algorithms
/ Analysis
/ Angiology
/ Background velocity offset error
/ Blood flow
/ Cardiac output
/ Cardiology
/ Cardiology and Cardiovascular Disease
/ Clinical Medicine
/ Clinical trials
/ Drift
/ Equipment Design
/ Europe
/ Humans
/ Image Interpretation, Computer-Assisted
/ Imaging
/ Kardiologi och kardiovaskulära sjukdomar
/ Klinisk medicin
/ Machinery
/ Magnetic resonance imaging
/ Magnetic Resonance Imaging, Cine - instrumentation
/ Magneto-electric machines
/ Marketing
/ Mechanical properties
/ Medical and Health Sciences
/ Medical research
/ Medicin och hälsovetenskap
/ Medicine
/ Medicine & Public Health
/ Medicine, Experimental
/ Offsets
/ Patients
/ Phantoms, Imaging
/ Phase-contrast velocity mapping
/ Physiological aspects
/ Predictive Value of Tests
/ Radiology
/ Regurgitation
/ Reproducibility of Results
/ Shunt flow
/ Speed
/ Stability
/ Technical Notes
/ Temporal logic
/ Time Factors
/ Whole Body Imaging - instrumentation
2012
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
A multi-center inter-manufacturer study of the temporal stability of phase-contrast velocity mapping background offset errors
by
Gatehouse, Peter D
, Kilner, Philip J
, Bloch, Karin Markenroth
, Rolf, Marijn P
, Hofman, Mark BM
, Graves, Martin J
, Firmin, David N
in
Acquisitions
/ Algorithms
/ Analysis
/ Angiology
/ Background velocity offset error
/ Blood flow
/ Cardiac output
/ Cardiology
/ Cardiology and Cardiovascular Disease
/ Clinical Medicine
/ Clinical trials
/ Drift
/ Equipment Design
/ Europe
/ Humans
/ Image Interpretation, Computer-Assisted
/ Imaging
/ Kardiologi och kardiovaskulära sjukdomar
/ Klinisk medicin
/ Machinery
/ Magnetic resonance imaging
/ Magnetic Resonance Imaging, Cine - instrumentation
/ Magneto-electric machines
/ Marketing
/ Mechanical properties
/ Medical and Health Sciences
/ Medical research
/ Medicin och hälsovetenskap
/ Medicine
/ Medicine & Public Health
/ Medicine, Experimental
/ Offsets
/ Patients
/ Phantoms, Imaging
/ Phase-contrast velocity mapping
/ Physiological aspects
/ Predictive Value of Tests
/ Radiology
/ Regurgitation
/ Reproducibility of Results
/ Shunt flow
/ Speed
/ Stability
/ Technical Notes
/ Temporal logic
/ Time Factors
/ Whole Body Imaging - instrumentation
2012
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
A multi-center inter-manufacturer study of the temporal stability of phase-contrast velocity mapping background offset errors
by
Gatehouse, Peter D
, Kilner, Philip J
, Bloch, Karin Markenroth
, Rolf, Marijn P
, Hofman, Mark BM
, Graves, Martin J
, Firmin, David N
in
Acquisitions
/ Algorithms
/ Analysis
/ Angiology
/ Background velocity offset error
/ Blood flow
/ Cardiac output
/ Cardiology
/ Cardiology and Cardiovascular Disease
/ Clinical Medicine
/ Clinical trials
/ Drift
/ Equipment Design
/ Europe
/ Humans
/ Image Interpretation, Computer-Assisted
/ Imaging
/ Kardiologi och kardiovaskulära sjukdomar
/ Klinisk medicin
/ Machinery
/ Magnetic resonance imaging
/ Magnetic Resonance Imaging, Cine - instrumentation
/ Magneto-electric machines
/ Marketing
/ Mechanical properties
/ Medical and Health Sciences
/ Medical research
/ Medicin och hälsovetenskap
/ Medicine
/ Medicine & Public Health
/ Medicine, Experimental
/ Offsets
/ Patients
/ Phantoms, Imaging
/ Phase-contrast velocity mapping
/ Physiological aspects
/ Predictive Value of Tests
/ Radiology
/ Regurgitation
/ Reproducibility of Results
/ Shunt flow
/ Speed
/ Stability
/ Technical Notes
/ Temporal logic
/ Time Factors
/ Whole Body Imaging - instrumentation
2012
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
A multi-center inter-manufacturer study of the temporal stability of phase-contrast velocity mapping background offset errors
Journal Article
A multi-center inter-manufacturer study of the temporal stability of phase-contrast velocity mapping background offset errors
2012
Request Book From Autostore
and Choose the Collection Method
Overview
Phase-contrast velocity images often contain a background or baseline offset error, which adds an unknown offset to the measured velocities. For accurate flow measurements, this offset must be shown negligible or corrected. Some correction techniques depend on replicating the clinical flow acquisition using a uniform stationary phantom, in order to measure the baseline offset at the region of interest and subtract it from the clinical study. Such techniques assume that the background offset is stable over the time of a patient scan, or even longer if the phantom scans are acquired later, or derived from pre-stored background correction images. There is no published evidence regarding temporal stability of the background offset.
This study assessed the temporal stability of the background offset on 3 different manufacturers' scanners over 8 weeks, using a retrospectively-gated phase-contrast cine acquisition with fixed parameters and at a fixed location, repeated 5 times in rapid succession each week. A significant offset was defined as 0.6 cm/s within 50 mm of isocenter, based upon an accuracy of 10% in a typical cardiac shunt measurement.
Over the 5 repeated cine acquisitions, temporal drift in the baseline offset was insignificant on two machines (0.3 cm/s, 0.2 cm/s), and marginally insignificant on the third machine (0.5 cm/s) due to an apparent heating effect. Over a longer timescale of 8 weeks, insignificant drift (0.4 cm/s) occurred on one, with larger drifts (0.9 cm/s, 0.6 cm/s) on the other machines.
During a typical patient study, background drift was insignificant. Extended high gradient power scanning with work requires care to avoid drift on some machines. Over the longer term of 8 weeks, significant drift is likely, preventing accurate correction by delayed phantom corrections or derivation from pre-stored background offset data.
Publisher
Elsevier Inc,BioMed Central,BioMed Central Ltd,Elsevier
Subject
/ Analysis
/ Background velocity offset error
/ Cardiology and Cardiovascular Disease
/ Drift
/ Europe
/ Humans
/ Image Interpretation, Computer-Assisted
/ Imaging
/ Kardiologi och kardiovaskulära sjukdomar
/ Magnetic Resonance Imaging, Cine - instrumentation
/ Medicine
/ Offsets
/ Patients
/ Phase-contrast velocity mapping
/ Speed
This website uses cookies to ensure you get the best experience on our website.