MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Cancer Screening: A Mathematical Model Relating Secreted Blood Biomarker Levels to Tumor Sizes
Cancer Screening: A Mathematical Model Relating Secreted Blood Biomarker Levels to Tumor Sizes
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Cancer Screening: A Mathematical Model Relating Secreted Blood Biomarker Levels to Tumor Sizes
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Cancer Screening: A Mathematical Model Relating Secreted Blood Biomarker Levels to Tumor Sizes
Cancer Screening: A Mathematical Model Relating Secreted Blood Biomarker Levels to Tumor Sizes

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Cancer Screening: A Mathematical Model Relating Secreted Blood Biomarker Levels to Tumor Sizes
Cancer Screening: A Mathematical Model Relating Secreted Blood Biomarker Levels to Tumor Sizes
Journal Article

Cancer Screening: A Mathematical Model Relating Secreted Blood Biomarker Levels to Tumor Sizes

2008
Request Book From Autostore and Choose the Collection Method
Overview
Increasing efforts and financial resources are being invested in early cancer detection research. Blood assays detecting tumor biomarkers promise noninvasive and financially reasonable screening for early cancer with high potential of positive impact on patients' survival and quality of life. For novel tumor biomarkers, the actual tumor detection limits are usually unknown and there have been no studies exploring the tumor burden detection limits of blood tumor biomarkers using mathematical models. Therefore, the purpose of this study was to develop a mathematical model relating blood biomarker levels to tumor burden. Using a linear one-compartment model, the steady state between tumor biomarker secretion into and removal out of the intravascular space was calculated. Two conditions were assumed: (1) the compartment (plasma) is well-mixed and kinetically homogenous; (2) the tumor biomarker consists of a protein that is secreted by tumor cells into the extracellular fluid compartment, and a certain percentage of the secreted protein enters the intravascular space at a continuous rate. The model was applied to two pathophysiologic conditions: tumor biomarker is secreted (1) exclusively by the tumor cells or (2) by both tumor cells and healthy normal cells. To test the model, a sensitivity analysis was performed assuming variable conditions of the model parameters. The model parameters were primed on the basis of literature data for two established and well-studied tumor biomarkers (CA125 and prostate-specific antigen [PSA]). Assuming biomarker secretion by tumor cells only and 10% of the secreted tumor biomarker reaching the plasma, the calculated minimally detectable tumor sizes ranged between 0.11 mm(3) and 3,610.14 mm(3) for CA125 and between 0.21 mm(3) and 131.51 mm(3) for PSA. When biomarker secretion by healthy cells and tumor cells was assumed, the calculated tumor sizes leading to positive test results ranged between 116.7 mm(3) and 1.52 x 10(6) mm(3) for CA125 and between 27 mm(3) and 3.45 x 10(5) mm(3) for PSA. One of the limitations of the study is the absence of quantitative data available in the literature on the secreted tumor biomarker amount per cancer cell in intact whole body animal tumor models or in cancer patients. Additionally, the fraction of secreted tumor biomarkers actually reaching the plasma is unknown. Therefore, we used data from published cell culture experiments to estimate tumor cell biomarker secretion rates and assumed a wide range of secretion rates to account for their potential changes due to field effects of the tumor environment. This study introduced a linear one-compartment mathematical model that allows estimation of minimal detectable tumor sizes based on blood tumor biomarker assays. Assuming physiological data on CA125 and PSA from the literature, the model predicted detection limits of tumors that were in qualitative agreement with the actual clinical performance of both biomarkers. The model may be helpful in future estimation of minimal detectable tumor sizes for novel proteomic biomarker assays if sufficient physiologic data for the biomarker are available. The model may address the potential and limitations of tumor biomarkers, help prioritize biomarkers, and guide investments into early cancer detection research efforts.