MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Standardisation of 18F using new portable 4πβ(LS) – λ coincidence detection system at ENEA-INMRI
Standardisation of 18F using new portable 4πβ(LS) – λ coincidence detection system at ENEA-INMRI
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Standardisation of 18F using new portable 4πβ(LS) – λ coincidence detection system at ENEA-INMRI
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Standardisation of 18F using new portable 4πβ(LS) – λ coincidence detection system at ENEA-INMRI
Standardisation of 18F using new portable 4πβ(LS) – λ coincidence detection system at ENEA-INMRI

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Standardisation of 18F using new portable 4πβ(LS) – λ coincidence detection system at ENEA-INMRI
Standardisation of 18F using new portable 4πβ(LS) – λ coincidence detection system at ENEA-INMRI
Conference Proceeding

Standardisation of 18F using new portable 4πβ(LS) – λ coincidence detection system at ENEA-INMRI

2023
Request Book From Autostore and Choose the Collection Method
Overview
This project concerned with the development at ENEA-INMRI of new in-situ 4πβ(LS) − λ coincidence detection system for activity measurement of the short half-life radionuclides used in Nuclear Medicine. The hardware of the new portable 4πβ(LS) − λ coincidence detection system was implemented at ENEA-INMRI, in collaboration with Catania University and INFN, by adding a gamma channel on the existing TDCR portable detector available at ENEA-INMRI. A new data analysis software was developed at CAEN, independently from an existing one elaborated at ENEA.INMRI, in order to analyse the data recorded in list-mode by the new detector equipped with the CAEN desktop digitizer DT5720. The activity for short half-life radionuclides used in nuclear medicine can be then computed. Two primary activity measurement TDCR and 4πβ(LS) − λ coincidence methods were then used to determine the activity of 18F at ENEA-INMRI. The TDCR parameter is measured for the 18F standard solution using both CAEN and ENEA-INMRI data analysis software.
Publisher
EDP Sciences