Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Research on Key Technologies for Measuring the Recovery Rate and Gas Measurement of SF6 Gas On-site Maintenance Surface
by
He, Shukai
, Wang, Sanxia
, Chen, Minjiang
, Wang, Xinghui
, Xu, Zhixin
, Zeng, Xiaozhe
, Chen, Da
, Cheng, Yingzhe
, Wang, Tenghui
in
Chambers
/ Deviation
/ Electric equipment
/ Electrical equipment
/ Emissions
/ Gas density
/ Gas recovery
/ High voltage
/ High voltages
/ Inspection
/ Onsite
/ Recycling
/ Voltage
2023
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Research on Key Technologies for Measuring the Recovery Rate and Gas Measurement of SF6 Gas On-site Maintenance Surface
by
He, Shukai
, Wang, Sanxia
, Chen, Minjiang
, Wang, Xinghui
, Xu, Zhixin
, Zeng, Xiaozhe
, Chen, Da
, Cheng, Yingzhe
, Wang, Tenghui
in
Chambers
/ Deviation
/ Electric equipment
/ Electrical equipment
/ Emissions
/ Gas density
/ Gas recovery
/ High voltage
/ High voltages
/ Inspection
/ Onsite
/ Recycling
/ Voltage
2023
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Research on Key Technologies for Measuring the Recovery Rate and Gas Measurement of SF6 Gas On-site Maintenance Surface
by
He, Shukai
, Wang, Sanxia
, Chen, Minjiang
, Wang, Xinghui
, Xu, Zhixin
, Zeng, Xiaozhe
, Chen, Da
, Cheng, Yingzhe
, Wang, Tenghui
in
Chambers
/ Deviation
/ Electric equipment
/ Electrical equipment
/ Emissions
/ Gas density
/ Gas recovery
/ High voltage
/ High voltages
/ Inspection
/ Onsite
/ Recycling
/ Voltage
2023
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Research on Key Technologies for Measuring the Recovery Rate and Gas Measurement of SF6 Gas On-site Maintenance Surface
Conference Proceeding
Research on Key Technologies for Measuring the Recovery Rate and Gas Measurement of SF6 Gas On-site Maintenance Surface
2023
Request Book From Autostore
and Choose the Collection Method
Overview
Carrying out full lifecycle management of SF6 gas recovery, purification, and recycling, developing new digital control technologies, and eliminating SF6 gas emissions from the source are of great significance for achieving the “dual carbon” goal. Given the low level of digital control of SF6 gas at present, especially in the situation, the SF6 gas recovery rate, the effective volume of the gas chamber, and gas weight cannot be accurately measured at an on-site inspection surface, this paper carries out research on SF6 gas recovery rate measurement at on-site inspection surface and key technologies of gas measurement. An intelligent online monitoring device such as SF6 gas recovery rate and effective chamber volume of high voltage electrical equipment was developed, which can quickly identify SF6 gas density, recovery rate, effective chamber volume, weight, and other parameters in high voltage electrical equipment, and evaluate the detection methods such as gas recovery rate and effective chamber volume. The results show that when the recovery rate was about 96.5%, the maximum positive deviation between the recovery rate measured by the detection device and that measured by the weighing method was 0.32% and the maximum negative deviation was -0.24%, both of which are less than 0.50%. When the container to be tested was 1000 L, the maximum indication error was -1.51%, which can meet the requirements of digital control in the SF6 gas recycling and reuse process of high-voltage electrical equipment.
This website uses cookies to ensure you get the best experience on our website.