MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Validation of the Electrophilic Allergen Screening Assay for Detection of Key Event 1 of the Skin Sensitization Adverse Outcome Pathway
Validation of the Electrophilic Allergen Screening Assay for Detection of Key Event 1 of the Skin Sensitization Adverse Outcome Pathway
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Validation of the Electrophilic Allergen Screening Assay for Detection of Key Event 1 of the Skin Sensitization Adverse Outcome Pathway
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Validation of the Electrophilic Allergen Screening Assay for Detection of Key Event 1 of the Skin Sensitization Adverse Outcome Pathway
Validation of the Electrophilic Allergen Screening Assay for Detection of Key Event 1 of the Skin Sensitization Adverse Outcome Pathway

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Validation of the Electrophilic Allergen Screening Assay for Detection of Key Event 1 of the Skin Sensitization Adverse Outcome Pathway
Validation of the Electrophilic Allergen Screening Assay for Detection of Key Event 1 of the Skin Sensitization Adverse Outcome Pathway
Journal Article

Validation of the Electrophilic Allergen Screening Assay for Detection of Key Event 1 of the Skin Sensitization Adverse Outcome Pathway

2026
Request Book From Autostore and Choose the Collection Method
Overview
The electrophilic allergen screening assay (EASA) uses small-molecule probes as surrogates for skin proteins to measure hapten protein carrier complex formation, Key Event (KE) 1 in the adverse outcome pathway for skin sensitization. Although multiple assays are accepted for this purpose, the EASA has higher throughput and needs less specialized equipment than other commonly used KE1 assays. This validation study assessed transferability of the EASA to naïve laboratories and within- and between-laboratory reproducibility. The predictive capacity of the assay in relation to reference data both from the murine local lymph node assay (LLNA) and, where available, human predictive patch tests, was estimated. The validation study was conducted using performance standards developed for methods that are under evaluation for inclusion in relevant test guidelines. The within- and between-laboratory reproducibility were cumulatively 96% and 85%, respectively. These scores exceeded the performance standard thresholds of 80%. Compared to reference LLNA data, the cumulative EASA results from the four laboratories had an overall sensitivity of 87%, specificity of 76%, and accuracy of 83%. The consensus results among the four laboratories had an overall sensitivity of 85%, specificity of 80%, and accuracy of 83%. For human reference data, the cumulative EASA results had an overall sensitivity of 81%, specificity of 76%, and accuracy of 70%. The EASA predicted sensitizers very well, although it had a slightly higher rate of misclassifying some negative test chemicals as positive with a specificity below the performance standards criterion of 80%. Our findings support further exploring use of the EASA in defined approaches to identify potential skin sensitizers.