Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
The impact of physiological noise correction on fMRI at 7T
by
Bernarding, J.
, Speck, O.
, Josephs, O.
, Featherstone, E.
, Reid, A.
, Stadler, J.
, Hutton, C.
, Weiskopf, N.
in
7 T
/ fMRI
/ Physiological noise
/ SNR
/ Temporal SNR
/ tSNR
2011
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
The impact of physiological noise correction on fMRI at 7T
by
Bernarding, J.
, Speck, O.
, Josephs, O.
, Featherstone, E.
, Reid, A.
, Stadler, J.
, Hutton, C.
, Weiskopf, N.
in
7 T
/ fMRI
/ Physiological noise
/ SNR
/ Temporal SNR
/ tSNR
2011
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
The impact of physiological noise correction on fMRI at 7T
Journal Article
The impact of physiological noise correction on fMRI at 7T
2011
Request Book From Autostore
and Choose the Collection Method
Overview
Cognitive neuroimaging studies typically require fast whole brain image acquisition with maximal sensitivity to small BOLD signal changes. To increase the sensitivity, higher field strengths are often employed, since they provide an increased image signal-to-noise ratio (SNR). However, as image SNR increases, the relative contribution of physiological noise to the total time series noise will be greater compared to that from thermal noise. At 7T, we studied how the physiological noise contribution can be best reduced for EPI time series acquired at three different spatial resolutions (1.1mm×1.1mm×1.8mm, 2mm×2mm×2mm and 3mm×3mm×3mm). Applying optimal physiological noise correction methods improved temporal SNR (tSNR) and increased the numbers of significantly activated voxels in fMRI visual activation studies for all sets of acquisition parameters. The most dramatic results were achieved for the lowest spatial resolution, an acquisition parameter combination commonly used in cognitive neuroimaging which requires high functional sensitivity and temporal resolution (i.e. 3mm isotropic resolution and whole brain image repetition time of 2s). For this data, physiological noise models based on cardio-respiratory information improved tSNR by approximately 25% in the visual cortex and 35% sub-cortically. When the time series were additionally corrected for the residual effects of head motion after retrospective realignment, the tSNR was increased by around 58% in the visual cortex and 71% sub-cortically, exceeding tSNR ~140. In conclusion, optimal physiological noise correction at 7T increases tSNR significantly, resulting in the highest tSNR per unit time published so far. This tSNR improvement translates into a significant increase in BOLD sensitivity, facilitating the study of even subtle BOLD responses.
► Impact of physiological noise correction on tSNR versus SNR was characterized at 7T. ► tSNR was improved by 50 to 70% using physiological noise correction in task-free EPI. ► The reported results exceed values for tSNR per unit time published so far. ► tSNR improvements translated into more than 10% increase in BOLD activity in fMRI.
Publisher
Elsevier Inc
Subject
This website uses cookies to ensure you get the best experience on our website.