MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Combined Approach to Stroke Thrombectomy Using a Novel Short Flexible Aspiration Catheter with a Stent Retriever
Combined Approach to Stroke Thrombectomy Using a Novel Short Flexible Aspiration Catheter with a Stent Retriever
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Combined Approach to Stroke Thrombectomy Using a Novel Short Flexible Aspiration Catheter with a Stent Retriever
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Combined Approach to Stroke Thrombectomy Using a Novel Short Flexible Aspiration Catheter with a Stent Retriever
Combined Approach to Stroke Thrombectomy Using a Novel Short Flexible Aspiration Catheter with a Stent Retriever

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Combined Approach to Stroke Thrombectomy Using a Novel Short Flexible Aspiration Catheter with a Stent Retriever
Combined Approach to Stroke Thrombectomy Using a Novel Short Flexible Aspiration Catheter with a Stent Retriever
Journal Article

Combined Approach to Stroke Thrombectomy Using a Novel Short Flexible Aspiration Catheter with a Stent Retriever

2022
Request Book From Autostore and Choose the Collection Method
Overview
Background Large-bore aspiration catheters enabling greater flow rates and suction force for mechanical thrombectomy might improve outcomes in patients with stroke secondary to large-vessel occlusion. Complete or near-complete reperfusion after a single thrombectomy pass (first-pass effect) is associated with improved clinical outcomes. We assessed the efficacy and safety of novel MIVI Q[TM] aspiration catheters in combination with stent-retriever devices. Methods We retrospectively analyzed demographics, procedure characteristics, and clinical data from consecutive patients with acute anterior large-vessel occlusion treated with a combined approach using MIVI Q[TM] aspiration catheters and stent retrievers. Reperfusion was defined according to the modified thrombolysis in cerebral infarction (mTICI) score. Clinical outcomes were measured by the National Institute of Health Stroke Scale (NIHSS) and modified Rankin scale (mRS) scores. Results We included 52 patients (median age, 75 y IQR: 64-83); 31 (59.6%) women; 14 (26.9%) with terminal internal carotid artery occlusions, 26 (50%) middle cerebral artery (MCA) segment M1 occlusions, and 12 (23.1%) MCA segment M2 occlusions; median NIHSS score at admission was 19 (IQR: 13-22). After the first pass, 25 (48%) patients had mTICIâ¯[greater than or equal to] 2c. At the end of the procedure, 47 (90.4%) had mTICIâ¯[greater than or equal to] 2b and 35 (67.3%) had mTICIâ¯[greater than or equal to] 2c. No serious device-related adverse events were observed. Symptomatic intracranial hemorrhage developed in 1 patient. Mean NIHSS score was 13â¯at 24â¯h and 5â¯at discharge. At 90 days, 24 (46.2%) patients were functionally independent (mRS 0-2). Conclusion This preliminary study found good efficacy and safety for MIVI Q[TM] aspiration catheters used in combination with stent-retriever devices.
Publisher
Springer,Springer Nature B.V