Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Familiarisation and reliability of sprint test indices during laboratory and field assessment
by
Galbraith, Andrew
, Wiles, Jonathan D
, Coleman, Damian A
, Hopker, James G
in
Analysis
/ Employment
/ Exercise physiology
/ Fitness equipment
/ Laboratories
/ Medicine
/ Metabolism
/ Outdoors
/ Protocol
/ Running
/ Scientists
/ Sport science
/ Sports medicine
/ Sprinting
/ Team sports
/ Test reliability
/ Tourism
/ Treadmill exercise tests
/ Warm up (exercise)
2009
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Familiarisation and reliability of sprint test indices during laboratory and field assessment
by
Galbraith, Andrew
, Wiles, Jonathan D
, Coleman, Damian A
, Hopker, James G
in
Analysis
/ Employment
/ Exercise physiology
/ Fitness equipment
/ Laboratories
/ Medicine
/ Metabolism
/ Outdoors
/ Protocol
/ Running
/ Scientists
/ Sport science
/ Sports medicine
/ Sprinting
/ Team sports
/ Test reliability
/ Tourism
/ Treadmill exercise tests
/ Warm up (exercise)
2009
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Familiarisation and reliability of sprint test indices during laboratory and field assessment
by
Galbraith, Andrew
, Wiles, Jonathan D
, Coleman, Damian A
, Hopker, James G
in
Analysis
/ Employment
/ Exercise physiology
/ Fitness equipment
/ Laboratories
/ Medicine
/ Metabolism
/ Outdoors
/ Protocol
/ Running
/ Scientists
/ Sport science
/ Sports medicine
/ Sprinting
/ Team sports
/ Test reliability
/ Tourism
/ Treadmill exercise tests
/ Warm up (exercise)
2009
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Familiarisation and reliability of sprint test indices during laboratory and field assessment
Journal Article
Familiarisation and reliability of sprint test indices during laboratory and field assessment
2009
Request Book From Autostore
and Choose the Collection Method
Overview
The aim of the study was to assess the reliability of sprint performance in both field and laboratory conditions. Twenty-one male (mean ± s: 19 ± 1 years, 1.79 ± 0.07 m, 77.6 ± 7.1 kg) and seventeen female team sport players (mean ± s: 21 ± 4 years, 1.68 ± 0. 07 m, 62.7 ± 4.7 kg) performed a maximal 20-metre sprint running test on eight separate occasions. Four trials were conducted on a non-motorised treadmill in the laboratory; the other four were conducted outdoors on a hard-court training surface with time recorded by single-beam photocells. Trials were conducted in random order with no familiarisation prior to testing. There was a significant difference between times recorded during outdoor field trials (OFT) and indoor laboratory trials (ILT) using a non-motorised treadmill (3.47 ± 0.53 vs. 6.06 ±1.17s; p < 0.001). The coefficient of variation (CV) for time was 2.55-4.22% for OFT and 5.1-7.2% for ILT. During ILT peak force (420.9 ± 87.7N), mean force (147.2 ± 24.7N), peak power (1376.8 ± 451.9W) and mean power (514.8 ± 164.4W), and were measured. The CV for all ILT variables was highest during trial 1-2 comparison. The CV (95% confidence interval) for the trial 3-4 comparison yielded: 9.4% (7.7-12. 1%), 7.9% (6.4-10.2%), 10.1% (8.2-13.1%) and 6.2% (5.1-8.0%) for PF, MF, PP and MP and respectively. The results indicate that reliable data can be derived for single maximal sprint measures, using fixed distance protocols. However, significant differences in time/speed over 20-m exist between field and laboratory conditions. This is primarily due to the frictional resistance in the non- motorised treadmill. Measures of force and power during ILT require at least 3 familiarisations to reduce variability in test scores. Key pointsReliable data can be derived from single maximal sprint measures in both indoor and outdoor environments using fixed distance protocols.There may be significant time differences to complete fixed distance trials between the two environments.Measures of mean force, peak force and peak power during indoor trials may require multiple trials to reduce variability in test scores.
Publisher
Journal of Sports Science and Medicine,Asist Group
Subject
This website uses cookies to ensure you get the best experience on our website.