MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Death incidents following transcatheter edge-to-edge repair registry
Death incidents following transcatheter edge-to-edge repair registry
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Death incidents following transcatheter edge-to-edge repair registry
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Death incidents following transcatheter edge-to-edge repair registry
Death incidents following transcatheter edge-to-edge repair registry

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Death incidents following transcatheter edge-to-edge repair registry
Death incidents following transcatheter edge-to-edge repair registry
Journal Article

Death incidents following transcatheter edge-to-edge repair registry

2025
Request Book From Autostore and Choose the Collection Method
Overview
The transcatheter edge-to-edge repair (TEER) technique, facilitated by the MitraClip device, is a minimally invasive intervention designed for high-risk patients with mitral regurgitation (MR). This study conducts a retrospective analysis of death events associated with MitraClip implantation over a ten-year decade, utilizing data from the FDA's Manufacturer and User Facility Device Experience (MAUDE) database to evaluate trends in safety outcomes. A comprehensive search of the publicly accessible MAUDE database was conducted to retrieve reports of deaths and injuries related to MitraClip implantation from October 2013 to September 2023. Duplicate reports and records from unrelated sources were excluded. The Cochran-Armitage test was performed to evaluate trends in the proportion of fatal events over time. During the 10-year period following FDA approval, the MAUDE database recorded a total of 927 death reports and 9,211 injury reports associated with MitraClip. After excluding duplicates and irrelevant reports, 592 death cases were analyzed. The most commonly reported complications were MR (26.69%), tissue damage (24.16%), and hypotension (22.13%). The most frequent device-related issues were incomplete coaptation (14.70%), difficulty removing the divice (6.42%), and failure to adhere or bond/positioning failure(4.90%). Notably, 76.94% of deaths occurred within one year of implantation. The proportion of fatal events demonstrated a gradual decline, from 15.9% in 2014-2015 to 3.5% in 2020-2021 (p < 0.0001). This analysis of the MAUDE database indicates a gradual decline in the proportion of fatal events associated with MitraClip implantation, which may be attributed to growing operator experience and advancements in device design. Nonetheless, persistent focus is required on managing complications and addressing potential risks to further enhance device performance and optimize its clinical utility.