MbrlCatalogueTitleDetail

Do you wish to reserve the book?
A 3P-3W UPQC with Scott-Connected Transformer for 3P-4W Distribution System
A 3P-3W UPQC with Scott-Connected Transformer for 3P-4W Distribution System
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
A 3P-3W UPQC with Scott-Connected Transformer for 3P-4W Distribution System
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
A 3P-3W UPQC with Scott-Connected Transformer for 3P-4W Distribution System
A 3P-3W UPQC with Scott-Connected Transformer for 3P-4W Distribution System

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
A 3P-3W UPQC with Scott-Connected Transformer for 3P-4W Distribution System
A 3P-3W UPQC with Scott-Connected Transformer for 3P-4W Distribution System
Journal Article

A 3P-3W UPQC with Scott-Connected Transformer for 3P-4W Distribution System

2011
Request Book From Autostore and Choose the Collection Method
Overview
In this paper, a new topology is developed for a three-phase four-wire (3P4W) distribution system utilizing a scott-transformer supported three-legs VSIs based three-phase three-wire (3P3W) Unified Power Quality Conditioner (UPQC).In this proposed topology the neutral point of the star connected transformer, used for the connection of series active power filter (APF) of 3P3W UPQC, is utilized as a fourth wire for 3P4W distribution system. The scott-connected transformer is connected near the load to compensate the neutral current that may flow toward the neutral point of the series transformer of series APF. For the mitigation of different power quality(PQ) problems a control technique based on the combination of unit template technique(UTT) and power balance theory(PBT)is used for the control of UPQC. In this control scheme of UPQC, the current/voltage control is applied over the fundamental supply currents/voltages instead of fast changing APFs currents/voltages, there by reducing the computational delay and the required sensors. The performance of the proposed topology of UPQC is analyzed through simulations results using MATLAB software with its Simulink and Power System Block set toolboxes. [PUBLICATION ABSTRACT]
Publisher
University of Oradea