Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
An Aboveground Pulse-Tube-Based Bolometric Test Facility for the Validation of the LUMINEU \\(\\hbox {ZnMoO}_4\\) Crystals
by
Sultan, A
, Gotti, C
, Pessina, G
, Shlegel, V N
, Giuliani, A
, Giachero, A
, Maino, M
, Ivanov, I M
, Mancuso, M
, Makarov, E P
, Danevich, F A
, Godfrin, H
, Dumoulin, L
, Olivieri, E
, Vasiliev, YaV
, Tenconi, M
, Chernyak, D M
in
Bolometers
/ Crystals
/ Low temperature physics
/ Pilots
/ Refrigerators
/ Russia
/ Signal to noise ratio
/ Test facilities
2014
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
An Aboveground Pulse-Tube-Based Bolometric Test Facility for the Validation of the LUMINEU \\(\\hbox {ZnMoO}_4\\) Crystals
by
Sultan, A
, Gotti, C
, Pessina, G
, Shlegel, V N
, Giuliani, A
, Giachero, A
, Maino, M
, Ivanov, I M
, Mancuso, M
, Makarov, E P
, Danevich, F A
, Godfrin, H
, Dumoulin, L
, Olivieri, E
, Vasiliev, YaV
, Tenconi, M
, Chernyak, D M
in
Bolometers
/ Crystals
/ Low temperature physics
/ Pilots
/ Refrigerators
/ Russia
/ Signal to noise ratio
/ Test facilities
2014
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
An Aboveground Pulse-Tube-Based Bolometric Test Facility for the Validation of the LUMINEU \\(\\hbox {ZnMoO}_4\\) Crystals
by
Sultan, A
, Gotti, C
, Pessina, G
, Shlegel, V N
, Giuliani, A
, Giachero, A
, Maino, M
, Ivanov, I M
, Mancuso, M
, Makarov, E P
, Danevich, F A
, Godfrin, H
, Dumoulin, L
, Olivieri, E
, Vasiliev, YaV
, Tenconi, M
, Chernyak, D M
in
Bolometers
/ Crystals
/ Low temperature physics
/ Pilots
/ Refrigerators
/ Russia
/ Signal to noise ratio
/ Test facilities
2014
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
An Aboveground Pulse-Tube-Based Bolometric Test Facility for the Validation of the LUMINEU \\(\\hbox {ZnMoO}_4\\) Crystals
Journal Article
An Aboveground Pulse-Tube-Based Bolometric Test Facility for the Validation of the LUMINEU \\(\\hbox {ZnMoO}_4\\) Crystals
2014
Request Book From Autostore
and Choose the Collection Method
Overview
The LUMINEU project aims at developing a pilot double beta decay experiment using scintillating bolometers based on ZnMoO \\(_4\\) crystals enriched in \\(100}\\hbox {Mo}\\) . In the next months regular deliveries of large-mass \\(\\hbox {ZnMoO}_4\\) crystals are expected from the Nikolaev Institute of Inorganic Chemistry (Novosibirsk, Russia). It is therefore crucial for the LUMINEU program to test systematically and in real time these samples in terms of bolometric properties, light yield and internal radioactive contamination. In this paper we describe an aboveground cryogenic facility based on a dilution refrigerator coupled to a pulse-tube cooler capable performing these measurements. A 23.8 g \\(\\hbox {ZnMoO}_4\\) crystal was fully characterised in this setup. We show also that macro-bolometers can be operated with high signal-to-noise ratio in liquid-free dilution refrigerators.
Subject
MBRLCatalogueRelatedBooks
Related Items
Related Items
This website uses cookies to ensure you get the best experience on our website.